background image

1

3

8

6

9

10

7

11

12

4

5

13

14

15

16

2

Internal view of Steripower 10041 / 10046

                10046 without socket        > operation only possible with rechargeable battery!

Available versions

10041 (with rechargeable battery)

10046 (high-frequency device)

10047 (with internal power supply unit)

10048 (with internal power supply unit + signalling)

10127 secure light

5

Summary of Contents for 10041

Page 1: ...BEDIENUNGSANLEITUNG OPERATING MANUAL STERIPOWER stainless steel edition white edition ...

Page 2: ...10041 10046 10046 without socket operation only possible with rechargeable battery Available versions 10041 with rechargeable battery 10046 high frequency device 10047 with internal power supply unit 10048 with internal power supply unit signalling 10127 secure light 5 ...

Page 3: ...ed circuit board 9 Space for disinfectant container 10 Collecting tray with Medical Pad 11 Control lamps LED 12 Service label 13 Solenoid valve 14 Pump unit 15 Sensor 16 Lid switch 17 Integrated power supply unit OVERVIEW DESCRIPTION 01 DESCRIPTION 17 The technical drawing for illustration purposes is located on the inside of the cover Internal view of Steripower art 10047 Steripower with power su...

Page 4: ...e The selection of the installation site place ment and installation of the device s shall be performed by technical personnel Overview and description 01 Transport dimensions and storage 03 Safety rules 04 Description and technical data 05 Removal and installation 06 Operation and operating principle 08 Maintenance and care 12 Electronic system 13 Troubleshooting 14 Operation manual for the lead ...

Page 5: ...otect against damage Protect against wet conditions Do not stack more cardboard boxes than indicated Open the packaging on the indicated side do not use pointed or sharp objects TRANSPORT Packaging sizes Height 220 mm x width 420 mm x length 530 mm Device dimensions approx Height 505 mm x width 290 mm x depth 200 mm DIMENSIONS Temperature 15 C bis 40 C STORAGE 530 mm 420 m m 220 mm 505 mm 200 mm 2...

Page 6: ...ecessary Knowledge relating to the performance and characteristics of the device must be present Only permitted disinfection liquids may be used The general hygiene provisions must be observed The device may under no circumstances be modified except for genuine spare parts otherwise the guarantee will be void Information labels attached to the device which were made illegible must be requested and...

Page 7: ...pc Charging device only for 10041 1 pc Collecting tray 1 pc Operation manual 1 pc Drilling template 1 pc Protective caps rechargeable battery 1 pack of screws dowels 1 pc Medical Pad Optional accessories Counter art 13010 S 07 Signalling art 01704 LED tunnel illumination art 01705 Wall panels Wall displays Stand up displays SCOPE OF DELIVERY ACCESSORIES Front cover with inspection windows Rear wal...

Page 8: ...charging is only possible with the cable correctly connected to the rechargeable battery refer to pg 01 item 7 5 Charging procedure Plug the charging device into the socket at the bottom of the device on the left refer to pg 01 item 5 The charging proce dure is continued as long as the LED of the char ging device is green Charging duration approx 24 hrs 6 Setting the quantity The liquid quantity i...

Page 9: ...replacing the device Attention the protective caps of the re chargeable battery serve against short circuit protection Only for Steripower with rechargea ble battery art 10040 10 Closing the device Put the front cover onto the device at an angle of 90 straight towards device Lift above the interlocking at the upper edge press at the lower part until latched Check the device for functionality 11 Co...

Page 10: ...m the device and rub the liquid for optimal germ elimination The automatic spraying device Steripower was specifically designed for hand hygiene purposes in order to ensure quick simple and effective disinfection of the hands Fields of application are for example hospitals medical practices reti rement and special care homes laboratories food and pharmaceutical industry hotel gastronomy industry a...

Page 11: ... refer to pg 6 item 6 DISINFECTION OF HANDS WHEN HANDLING FOOD Disinfecting the hands is required to avoid contamination of food with germs of any kind Disinfection must be performed for example following Eating visits to the toilet smoking raw material change chicken vegetables egg etc in order to avoid transfer of germs Touching the food with disinfected hands does not affect the food Hands that...

Page 12: ... or down the suction pipe Always cover the liquid container with the plug in order to avoid evaporation of the liquid Move the front cover horizontally towards the device put it on at the top and press the lower part until latched Have the liquid sucked into the device by triggering the sensor several times REPLACING THE LIQUID CONTAINER If the device was not used for a longer period first rinse w...

Page 13: ...evice Do not under any circumstances use a damaged charging device or power supply unit If the charging device or power supply unit are defective or damaged they may only be replaced by a genuine spare part The rechargeable battery must be disposed of in a proper manner and not via household waste Rechargeable batteries can be disposed of in collection centres of the public waste management organi...

Page 14: ...sh with water do not use pressurised air and solvents in order to remove dirt or residues If the device is to be reused after a long period not in use rinse the system several times with pure alcohol This is done in order to remove possible clogging Charge the rechargeable battery for 24 hrs and then loosen the positive pole and secure it with a protective cap yellow MAINTENANCE CARE Alcohol ethan...

Page 15: ...ug for motor pump E Plug for non return valve F Plug for rechargeable battery 12 V 7 Ah G Fuse 1 6 A delayed action fuse H LED green for operation I LED red signal J LED blue counter K Sensor L Fine tuning M Plug for cover contact N Plug for LED activity lamp ELECTRONIC SYSTEM D B E F G H I J A M K C L N EN ELECTRONIC SYSTEM 13 ELECTRONIC SYSTEM ...

Page 16: ...m to top Screw off the red nozzle and clean the tiny hole of the jet opening with a thin needle Screw on the red nozzle and adjust the correct spray jet cone shaped by screwing down or unscrewing Then insert the pump in the support and lock it in position If the measures taken are unsuccessful inform the service refer to service label pg 01 item 12 The liquid quantity is too high or to low Regulat...

Page 17: ...the rechargeable battery of the device for 24 hrs every 4 weeks with approx 100 usages per day you can avoid malfunctions The device is constantly dripping The valve must be replaced Request valve art 11150 or contact service hotline refer to ser vice label pg 01 item 12 Liquid is leaking out of the device Medical Pad art 12020 in the collecting tray is no longer absorbent and must be replaced It ...

Page 18: ... wall socket Once the electrical contact is applied the charging procedure starts automatically The LED flashes green and indicates the charging procedure Once the charging procedure is completed the LED turns off The rechargeable battery continues to be buffered with a float charging current following the charging procedure Once the charging device is disconnected from the mains the rechargeable ...

Page 19: ...housing or the mains plug is damaged In case of defects please contact an authorised dealer or service steripower de The charging device may only be operated in closed and dry rooms In order to exclude the risk of fire or the risk of an electric shock the device must be protected against humidity READINESS AND PARALLEL OPERATIONAL WARNING SAFETY NOTE CARE SERVICE eMail service steripower de Telefo...

Page 20: ... article du produit mit den folgenden Normen bzw normativen Dokumenten übereinstimmt is in accordance with the following standards or standardized documents est conforme aux normes ou spécifications Européennes suivantes 1 EN 61 000 6 3 2001 Störaussendungen EMA RF emission EN 61 000 3 2 2000 Oberschwingungen harmonics EN 61 000 3 3 1995 A1 2001 Spannungsschwankungen flicker 2 EN 61 000 6 1 2001 S...

Page 21: ...STERIPOWER GmbH Co KG Schiffbauerweg 1 D 82319 Starnberg www steripower de info steripower de made by spleen de ...

Reviews: