background image

 

 

 

T

ROUBLESHOOTING

 

Symptom 

Possible Causes 

Corrective Action 

Emitter does not light 

Cover Off/interlock switch open 

Install cover/depress interlock switch 

Momentary loss of power. 

Reset Power Turn off power for 10 
Seconds, and then turn power on. 

Poor connection 

Check connection to emitter.  Check 
wiring connections. Reset Power  

Incorrect wiring 

Inspect circuit to wiring diagram. 

Dirty pins 

Clean pins. Reset Power 

System malfunction 

Check system components, interlock 
door switches, relays, motion 
detectors, etc. 

Emitter reaching end of life 

Replace with new Emitter. Reset 
Power 

Defective Power supply 

Replace Power Supply.  

Visibly Weak Emitter 
Light 

Bad Wiring 

Check wiring to emitter 

Emitter reaching end of life 

Replace Emitter 

Emitter too Cold 

If emitter is at or below 35°F(1°C), 
Emitter is too cold to operate properly.  

Red/Orange Emitter 

Emitter reaching end of life 

Replace Emitter 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

I

TEM

  D

ESCRIPTION

 

P

ART 

N

UMBER

 

Power Supply

 

10000189

 

Switch On/Off 

11000112 

Switch Interlock 

11000113 

Support Bracket 

12000501 

4-40 Nylon Insert Locknut 

11000115 

Spring 

11000104 

O-Ring 

11000105 

Summary of Contents for ESE 1 Series

Page 1: ...er may result Oil from fingerprints will permanently etch glass of Emitter and weaken structure If necessary clean Emitter using a Steril Aire cleaning kit isopropyl alcohol and a lint free wipe may be substituted UVC Emitters are fragile To prevent accidental breakage handle the UVC Emitter with care Voltages outside of the range designed for the unit will void the warranty and do permanent damag...

Page 2: ...stance equal to half the vertical height that the light is covering 6 The Emitter shall also o Be at least 1 away from any heating coil o Not make contact with the air handler blower 7 If applicable replace the outer cover of air handler 8 Remove cover to ESE Fixture 9 Using the fixture base as a template scribe and then create an insertion hole 2 diameter where you want the emitter to be located ...

Page 3: ...components interlock door switches relays motion detectors etc Emitter reaching end of life Replace with new Emitter Reset Power Defective Power supply Replace Power Supply Visibly Weak Emitter Light Bad Wiring Check wiring to emitter Emitter reaching end of life Replace Emitter Emitter too Cold If emitter is at or below 35 F 1 C Emitter is too cold to operate properly Red Orange Emitter Emitter r...

Page 4: ... been investigated by UL 2017 Steril Aire Inc All rights reserved 1391 REPLACEMENT PARTS PART NUMBER EGTS 24 VO Enhanced 24 Single Ended Emitter 21000310 EGTS 30 VO Enhanced 30 Single Ended Emitter 21000410 EGTS 36 VO Enhanced 36 Single Ended Emitter 21000510 EGTS 42 VO Enhanced 42 Single Ended Emitter 21000610 EGTS 50 VO Enhanced 50 Single Ended Emitter 21000910 EGTS 61 VO Enhanced 61 Single Ende...