background image

4

Overview

Description:

Crank-handle to adjust the interaxials between 90 mm and XXX mm

Motorization (optional) for the interaxial adjustment, otherwise locking screw

Rotary table with optional motorization and optional tilting module for camera fine adjust

-

ment roll

Adjustment wheel with electronic counter (resetable for calibration; with computation in 

degrees) and optional motorization

Non-rotary table with optional tilting module for camera fine adjustment tilt

Tripod mounting plate

Electronic counter for the interaxial distance (resetable for calibration; with computation 

in degrees)

Camera adapter plate and optional mount for Chrosziel quicklock plate

1

2

3

4

5

6

7

8

9

Summary of Contents for Side-by-Side Rig

Page 1: ...Side by Side Rig User Manual English Version 1 0 Before operating this product please read the instruction carefully and save this manual for future use CEV FR ...

Page 2: ... send an e mail to info stereotec com Concerning any service and warranty requests please contact your distributor or stereotec Stereoscopic Technologies GmbH directly What s in the Box Interaxial control with the basic module length on customers requests with high quality electronic counter resetable for calibration with computation in degrees and crank handle motorizable Rotary table s with fine...

Page 3: ...aintenance Special Tools Do not touch glass components with sharp objects For cleaning do only use spe cial lens cleaning supplies Refer all servicing to qualified service personnel Storage Please store the Side by Side Rig in a dry and dust free place Disposal Please dispose broken components and devices correctly Site of operation Do not use the Side by Side Rig in flying vehicles like helicopte...

Page 4: ...a fine adjust 3 ment roll Adjustment wheel with electronic counter resetable for calibration with computation in 4 degrees and optional motorization Non rotary table with optional tilting module for camera fine adjustment tilt 5 Tripod mounting plate 6 Electronic counter for the interaxial distance resetable for calibration with computation 7 in degrees Camera adapter plate and optional mount for ...

Page 5: ...mplete setup rig 2x cameras 2x lenses Mounting Cameras Camera Plate The camera plates 8 are screwed on the rotary table 3 and the non rotating table 5 To mount or unmount the camera plate from the table use the Allen key screwdriver to tighten or loosen the screws e on the rear side After releasing the camera plate 8 from the table 3 or 5 choose the adequate screws a c or d to mount the plate on t...

Page 6: ... counter 7 Only if the calibration got lost or the set screw looses by mistake Then move the tables to a distance of exact 90 mm middle to middle loose the set screw in the setting ring and adjust the setting ring until the display shows 90 0 Tighten the set screw in the end Before turning the crank handle 1 be sure the locking screw 2 on the other end of the Side by Side Rig is loose After intera...

Page 7: ...for a horizontal line in the scenery e g a forest line a row of houses or even a sky line then aim with the camera setup on the rig at this line While adjusting the camera roll look at the stereoscopic screen When the lines of both pic tures are parallel the roll angle is adjusted correctly Adjusting Camera Tilt Proceed as same as for the camera roll Search a line in the scenery and when the lines...

Page 8: ...e as used also for other camera extensions Rotary Table Motorization First the electronic counter must be removed Use a 1 5 mm Allen key to loosen the head less screw in the turning knob Then pull the knob to remove it Use a 2 0 mm Allen key to loosen the head less screw in the ring in front of the electronic counter Then pull the counter to remove it Beyond mount the motorizing bracket for the mo...

Page 9: ...Copyright stereotec Stereoscopic Technologies GmbH 2009 ...