background image

0418m

V0.0

1 2 3
4 5 6
7 8 9

0 #

POWER

DOOR

BELL

OK

MODE

RFID

Manual de instrucciones

SEG-155

CONTROL DE ACCESO

Summary of Contents for SEG-155

Page 1: ...0418m V0 0 1 2 3 4 5 6 7 8 9 0 POWER DOOR BELL OK MODE RFID Manual de instrucciones SEG 155 CONTROLDEACCESO...

Page 2: ...icas de baja frecuencia Especialmente en el rango de 100 200 kHz b Si hay m s de un Control de Acceso operando en la misma frecuencia procure que est n separados por lo menos 60 cm para evitar interfe...

Page 3: ...E Contenido Partes Conexi n de terminales Tonos y se ales del sistema Cancelaci n de comandos Operaci n del equipo C digos a par metros de f brica Soluciones y problemas Especi caciones 3 3 4 5 5 6 10...

Page 4: ...ENIDO PARTES Control de acceso Teclado num rico Timbre Indicadores LED Panel de conexiones Lector de tarjeta Tornillos y Taquetes PANEL FRONTAL PANEL POSTERIOR DOOR1 DGND OPENSW PUSH NO NC GND BELL BE...

Page 5: ...errada dirigida al negativo de la chapa Conexi n de tierra Voltaje de alimentaci n Timbre Ver diagrama de referencia Timbre Ver diagrama de referencia Interruptor de apertura de puerta No mover Conexi...

Page 6: ...ot npresionadoaceptado Mododeprogramaci n Comandodeprogramaci nv lido Comandodeprogramaci nv lido IndicadorLEDrojo encendido encendido encendido encendido encendido encendido encendido encendido Indic...

Page 7: ...Presione 0 6 nuevos d gitos Con rme los 6 nuevos d gitos Modi car el c digo de programaci n 001 500 Para borrar la tarjeta s lo podr hacerlo con n meros de usuario que soporta el sistema desde 001 ha...

Page 8: ...nido 2 sonidos C digos ID de usuario que desee borrar Borrar tarjeta con lector de tarjeta Presione 7 Coloque la Tarjeta 1 en el lector Coloque la Tarjeta 2 en el lector Con gurar modo de apertura de...

Page 9: ...nsor de alarma Presione 8 0 Activar el sensor de alarma Presione 8 1 TT es el intervalo de tiempo en segundos Por ejemplo si el tiempo de retraso de alarma es de 3 segundos ser TT 03 Esta funci n se r...

Page 10: ...s despu s de 5 segundos entre al modo de con guraci n Presione la tecla C digo de programaci n C digo por defecto 990101 Posteriormente se restablecer n los valores predeterminados de f brica Restable...

Page 11: ...a 990101 C digo p blico o de tarjeta 1234 3 segundos Desactivado Desactivado 0 segundos Problema Soluci n Despu s de abrir la chapa de la puerta se escuchan 8 sonidos cortos El control necesita un vol...

Page 12: ...prolongado y no permite accederalmododeprogramaci n Otras teclas fueron presionadas antes de presionar la tecla Mantenga presionada la tecla despu sde escucharunsonidoprolongado intenteaccederalmodo...

Page 13: ...lico 1 Frecuencia de lectura interna Modo ID 125 kHz Modo IC 13 56 MHz Proximidad de tarjeta Modo ID EM o compatible Modo IC Mifare 1 o compatible ESPECIFICACIONES Distancia de lectura de tarjeta Modo...

Page 14: ......

Page 15: ...0418m V0 0 1 2 3 4 5 6 7 8 9 0 POWER DOOR BELL OK MODE RFID Instruction manual SEG 155 ACCESS CONTROL...

Page 16: ...tromagnetic waves especially in the 100 200kHz range b If there are more than one Access Control operating in the same frequency make sure they are separated by at least 60cm to avoid interference 2 S...

Page 17: ...2 INDEX Content Parts Terminals connection System tones and signals Cancel commands Operating Factory default pin Troubleshooting Speci cations 3 3 4 5 5 6 10 11 12...

Page 18: ...3 CONTENT PARTS Access control Numeric keyboard Bell LED indicators Connection panel Card reader Screws and Tacks FRONT PANEL REAR PANEL DOOR1 DGND OPENSW PUSH NO NC GND BELL BELL 12V...

Page 19: ...y closed terminal directed to the negative of the door lock Ground connection Supply voltage Bell See reference diagram Bell See reference diagram Door opening switch Do not move 2 3 connection Door l...

Page 20: ...xitbutton Wrongcodeentered Unauthorizedcardreading Pressedbuttonaccepted Programmingmode Validprogrammingcommand Validprogrammingcommand RedLEDindicator on on on on on on on on GreenLEDindicator on on...

Page 21: ...OPERATING Programming mode Press 0 6 new digit PIN Con rm the 6 new digit PIN Modify the programming pin 001 500 To delete the card you can only do so with user numbers that the system supports from...

Page 22: ...2 beeps 1 beep 2 beeps 1 beep 2 beeps User ID codes that you want to delete Delete card by presenting card Press 7 Presenting Card 1 Presenting Card 2 Set up door opening mode with card or pin Press 1...

Page 23: ...the control Disable the door sensor alarm Press 8 0 Enable the door sensor alarm Press 8 1 TT is the time interval in seconds For example if the alarm delay time is 3 seconds it will be TT 03 This fu...

Page 24: ...ou will hear 2 beeps after 5 seconds enter to the con guration mode Press Programming pin PIN Default 990101 Subsequently the factory default values will be restored Reset programming pin Remove the c...

Page 25: ...90101 Card or public pin 1234 3 seconds Disabled Disabled 0 seconds Trouble Solution After opening the door lock you will hear 8 short beeps The control needs a higher voltage check the power supply T...

Page 26: ...Programmingpin there is long beep and can not entertotheprogrammingmode Other keys were pressed before pressing the key Hold down the key after hearing a long sound try entering the programming mode a...

Page 27: ...c PIN 1 Internal reader frequency ID model 125 kHz IC model 13 56 MHz Proximity card ID model EM or compatible IC model Mifare 1 or compatible SPECIFICATIONS Card reading distance ID model 5 15 cm IC...

Page 28: ......

Reviews: