30
30
20. Specifi cation tables
Direct voltage
Input impedance: 10 MΩ
Maximum input voltage: 250V DC or AC rms for the range of
200 mV and 600 V DC or AC 600 V rms for other ranges.
Range
Accuracy
200mV
2V
20V
200V
1000V
+- (0.5% of rdg + 2 digits)
+- (0.8% of rdg + 2 digits)
0.1mV
1mV
10mV
100mV
1V
Resolution
Alterning voltage
Input impedance: 10 M
Ω
Maximum input voltage: 250V DC or AC rms for the range of 200 mV and
600 V DC or AC 600 V rms for other ranges.
Frequency range: 40 Hz-400 Hz
Response: Average, calibrated in rms of sine wave.
Range
Accuracy
2v
20V
200V
600V
+-(0.8% of rdg + 3 digits)
+- (1.2% of rdg + 3 digits)
1mV
10mV
100mV
1V
Resolución
V
600V