Stellar Pump Australia
`
9
Installation, Operation and Maintenance (IOM) Manual
b.
Electric motor
i.
Check the termination of wires or cables inside the terminal box. Retighten the bolts
and screw if necessary.
ii.
Bearings should be checked thoroughly. Please refer section VII. #2 for reference.
iii.
Measure the motor insulation using insulation tester if it is within the normal range.
iv.
Check body temperature of electric motor. Standard body temperature of electric
motor ranges from 40
o
C to 60
o
C
SECTION VIII. SPARE PARTS
1.
Recommended Spare Parts for HESC Series Horizontal End Suction Close-Coupled Pump
a.
Intermittent duty
*Item
Description
5, 5.1
Front and back wear ring
8
Set of Mechanical Seal
4
Casing Gasket
* Refer to Section IX for reference
b. Continuous operation
*Item
Description
5, 5.1
Front and back wear ring
8
Set of Mechanical Seal
4
Casing Gasket
6
Impeller
-
Motor bearings (Not shown)
15, 18
Key
3, 3.1, 3.2
Nut, flat washer, spring washer
16
Shaft
17
screw
2.
Recommended Spare Parts for HESB Series Horizontal End Suction Bare Shaft Pump
a.
Intermittent duty
*Item
Description
3, 3.1
Front and back wear ring
6
Shaft spacer
**7, 8.1
Set of Mechanical Seal
***15, 16,
17
Set of Packing Gland
19
Casing Gasket
* Refer to Section IX for reference
** If type of seal is mechanical
*** If type of seal is packing gland