background image

Stellar Pump Australia  

 
 
 
 
 

13 

 

Installation, Operation and Maintenance (IOM) Manual 

 

3.

 

VISC Series Vertical In-line Single Stage Pump 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Item 

Description 

Pump Casing 

Impeller Nut 

Flat Washer 

Spring Washer 

Front Wear Ring 

Impeller 

Seal Seat 

Mechanical Seal 

Casing Gasket 

10 

Casing Cover 

11 

1/4 Plug 

12 

Adapter 

13 

Guard 

14 

Screw 

15 

Screw Bolt 

16 

Screw Nut 

17 

Screw Bolt 

18 

1/4 Plug 

19 

3/8 Plug 

20 

Key 

21 

Screw Nut 

22 

IEC Electric Motor 

23 

Key 

24 

Screw 

25 

Shaft 

Summary of Contents for HESB Series

Page 1: ...llation Operation Maintenance Manual HESC Series Horizontal End Suction Close Coupled Pump HESB Series Horizontal End Suction Bare Shaft Pump VISC Series Vertical In Line Singe Stage Pump HESC Pump HE...

Page 2: ...umbers are not on the list it means The list is not yet updated quarterly updating the Authentic page It has been removed to accommodate newly registered serial numbers The product s that you have rec...

Page 3: ...X Exploded View Page 11 Section X Trouble Shooting Page 14 SECTION I INTRODUCTION STELLAR PUMP HESC series horizontal end suction close coupled pump HESB series horizontal end suction bare shaft pump...

Page 4: ...of this pump SECTION III WARRANTY CONDITION This warranty applies against all defective materials and or faulty manufacture for the period of One 1 year from the date of shipment unless specifically s...

Page 5: ...or plinth as long as surface is properly level b Pump can be installed with rubber isolation spring isolation or inertia base to avoid transfer of vibration during operation Kindly refer to manufactu...

Page 6: ...f wires and cables for electric motor shall be in accordance to related electrical code local regulations b Wire or cable sizes must be appropriate to Kilowatt kw or Horsepower hp rating of electric m...

Page 7: ...erature vibration could damage the ceramic coating of mechanical seal ii Presence of solid particles in water could also damage the mechanical seal iii Misalignment of pump and or motor shaft could al...

Page 8: ...o overheat c Bearings should be replaced every 10000 working hours 3 Mechanical Seal a Presence of high temperature in pump volute excessive vibration and poor quality of water will damage the ceramic...

Page 9: ...C Series Horizontal End Suction Close Coupled Pump a Intermittent duty Item Description 5 5 1 Front and back wear ring 8 Set of Mechanical Seal 4 Casing Gasket Refer to Section IX for reference b Cont...

Page 10: ...il Seal 33 Bushing gasket Refer to Section IX for reference If type of seal is mechanical If type of seal is packing gland 3 Recommended Spare Parts for VISC Series Vertical In line Single Stage Pump...

Page 11: ...n 1 Pump Casing 2 Plug 2 1 Plug Spacer 3 Nut 3 1 Flat Washer 3 2 Spring Washer 4 Casing Gasket 5 Front Wear Ring 5 1 Back Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Cover 10 Adapter I...

Page 12: ...er 10 Bearing Housing 11 Shaft 12 Bearing 13 Bearing Cover Item Description 14 Support 14 1 Flat Washer 14 2 Elastic Washer 14 3 Screw Bolt 15 Packing Sleeves 16 Packing Seal Cage 17 Packing Gland 18...

Page 13: ...scription 1 Pump Casing 2 Impeller Nut 3 Flat Washer 4 Spring Washer 5 Front Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Gasket 10 Casing Cover 11 1 4 Plug 12 Adapter 13 Guard 14 Screw...

Page 14: ...s motor HP 6 Remove solid particles 7 Replace wear ring Excessive noise and vibration 1 Trap air or leak at suction pipe 2 Impeller direction wrong 3 Misalignment 4 Bearings operating dry condition 1...