Page 26
INSTALL_3-RD-GL-R REV A
9 - VENTING
Available Power Venting
A power vent (RS-12 & RS014) is approved for use with
this appliance. It is crucial that all B-Vent pipe and elbow joints, and the longitudinal seam are
sealed using a high temperature RTV Silicone and/or foil tape.
MODEL
RS012
RS014
Fan Type
Axial vane
Axial vane
Motor Type
Totally enclosed, vari
-
able speed, Class H
Totally enclosed, variable
speed, Class H
Voltage (VAC)
1 x 120
1 x 120
RPM
1600
1600
CFM
950
1400
Amperage (Amps)
1.2
1.4
Motor Output HP (kW)
1/9 (0.08)
1/7 (0.1)
Weight lbs (kg)
37 (17)
47 (21)
Dimension A in. (mm)
11.5 (292)
13.1 (334)
Dimension B x B in.(mm)
14.3 (364)
16.6 (422)
Dimension C in. (mm)
13.5 (344)
15.5 (395)
Dimension D in. (mm)
3.3 (85)
3.9 (100)
Dimension E in. (mm)
11.6 (294)
13.5 (342)
Temperature Rating-Intermittent
575 °F / 300 °C
575 °F / 300 °C
Temperature Rating-Continuous
482 °F / 250 °C
482 °F / 250 °C
Figure 9D
HOLE SPACING
13-1/4 IN.
337 mm
INSIDE FLANGE
14-1/2 IN.
368 mm
HOLE DIAMETER
3/8 IN.
10 mm
HOLE DIAMETER
3/8 IN.
10 mm
HOLE SPACING
14-11/16 IN.
373 mm
INSIDE FLANGE
17-1/8 IN.
435 mm
Figure 9E.1 8 Inch Chimney Collar Dimensions (RS012)
Figure 9E.2 10 Inch Chimney Collar Dimensions (RS014)
Chimney Collar Dimensions
A chimney collar is included for use with the RS012 and RS014. The chimney collar is used to attach the RS power vent.
Figures 9E.1 and 9E.2 show the dimensions of the chimney collar.
D. RS SERIES POWERVENT SPECIFICATIONS
E. CHIMNEY COLLAR DIMENSIONS