CONSUMABLES LIST

 

EXPLODED VIEW TORCH 

DESCRIPTION 

CODE 

DEFAULT 

 
Tip Cutting Drag 30A 9-8206 
Tip Cutting Drag 40A 9-8207 
Tip Cutting Drag 60A 9-8252 
Tip Cutting 60A   9-8210 
Tip Cutting 100A  9-8212 
Tip Cutting Gouging 60A 9-8226 
Tip Cutting Gouging 100A 9-8228 
Electrode 9-8215 
Shield Cup Body Maximum Life 9-8237 
Shield Cup Body 9-8218 
Shield Cup Cutting 60A 9-8235 
Shield Cup Cutting 100A 9-8236 
Shield Cup Gouging 9-8241 
Stand off Guide 9-8281 
Deflector 9-8243 
Start Cartridge 9-8213 
Torch Head 9-8219 
1Torch 6m SL60 7-5253 
1Torch 6m SL100 7-5254 

 

601048000L 
607380000L 
601238000L 
607390000L 
607400000L 
609950000L 
609450000L 
607360000L 
6074100000 
600617000L 
6074200000 
6074300000 
6099700000 
6009950000 
6074400000 
6073700000 
6099800000 
607340000L 
607350000L 

 
 
 
 
 

 
 


 
 
 
 
 
 


  

DESCRIPTION 

CODE 

N° 

 
Handle Replacement Kit                    (included 2 and 3) 
Trigger Assembly Replacement kit 
Handle Screw kit  (5 pcs) 
Torch Head Assembly                     (included 5 and 6) 
O-Ring Ø 21x1,7 black 
O-Ring Ø16 x 1.4 Red 
Switch kit 

 

600715 
600716 
600717 
609980 
600577 
600578 
600714 

 







  

Summary of Contents for THOR 123

Page 1: ...6934900000 1 MANUALE DI ISTRUZIONE PER TAGLIO PLASMA INSTRUCTION MANUAL FOR PLASMA CUTTING MACHINE THOR 123 THOR 123 THOR 123 THOR 123 Info www stelgroup it tel 39 0444 639525...

Page 2: ...ww stelgroup it The following harmonized standard in force within the EEA has been used in the design EN 60974 1 ed 4 Arc welding equipment Part 1 Welding power sources EN 60974 10 ed 2 Arc welding eq...

Page 3: ...ficiente usare un aspiratore che aspiri dal basso IL CALORE GLI SCHIZZI DEL METALLO FUSO E LE SCINTILLE POSSONO PROVOCARE INCENDI Non saldare vicino a materiali infiammabili Evitare di portare con s q...

Page 4: ...ratore necessita di aria compressa L aria usata dovr essere priva di impurit olio acqua od altri prodotti inquinanti RICEVIMENTO L imballo contiene N 1 generatore N 1 manuale istruzione N 1 cavo massa...

Page 5: ...un adeguato interruttore munito di fusibili ritardati MESSA A TERRA Per la protezione degli utenti il generatore dovr essere assolutamente collegato correttamente all impianto di terra NORMATIVE INTER...

Page 6: ...oder regolazione corrente MESSA IN OPERA L operatore addetto durante l utilizzo della macchina deve obbligatoriamente porsi nel lato anteriore della stessa onde evitare che i fumi prodotti dal taglio...

Page 7: ...taglio MALFUNZIONAMENTI COMUNI DURANTE IL TAGLIO Il pezzo non completamente forato Le cause possono essere La corrente troppo bassa La velocit di taglio troppo alta I componenti della torcia sono con...

Page 8: ...ate o altre come vetro plastica e metallo MANUTENZIONE DELLA TORCIA A Pulizia della torcia Anche se si adottano precauzioni per utilizzare soltanto aria pulita con la torcia possibile che all interno...

Page 9: ...la ove del caso 5 Estrarre l elettrodo direttamente dal corpo torcia Verificare che la faccia dell elettrodo non presenti un usura eccessiva facendo riferimento alle figure di seguito 6 Rimontare l el...

Page 10: ...ssivamente 3 Protezione sicurezza torcia o malfunzionamento dell interruttore della torcia a Verificare che la shield cup sia montata correttamente b Controllare la continuit dell interruttore nell im...

Page 11: ...servare se presente una formazione di olio o umidit non azionare la torcia DIFETTI In questa sezione vengono descritti I pi comuni malfunzionamenti e come vengono indicati MANCANZA ARIA Il led 1 di pr...

Page 12: ...unte a fine vita devono essere raccolte separatamente e conferite ad un impianto di riciclo ecocompatibile In qualit di proprietario delle apparecchiature dovr informarsi presso il nostro rappresentan...

Page 13: ...OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the welding mac...

Page 14: ...ust be free from impurities oil or other polluting substances DELIVERY OF THE MATERIAL The package contains N 1 Inverter N 1 instructions manual N 1 torch N 1 earth cable N 1 air connection Check that...

Page 15: ...pe fuse s In the event of damage to the power cable replacement or repair must be performed by a qualified person at an approved service centre EARTHING To ensure user protection the Inverter must by...

Page 16: ...er having read and understood all parts of this manual Depending on the type of cut to be performed he must follow the work phases described below 1 Ensure that the work environment and your clothing...

Page 17: ...the torch facing away from your body and bring it slowly into the vertical position This is important when cutting thick gauges Ensure that the torch is pointed away from you and from anyone else in t...

Page 18: ...NNECT INPUT PRIMARY SUPPLY Disconnect primary power at the source before disassembling of torch leads Frequently review the important safety precautions at the front of this Manual Be sure the operato...

Page 19: ...ge Check for excessive wear plugged gas holes or discolouration Check the lower end fittings for free motion Replace if necessary 5 Pull the electrode straight out of the torch head Check the face of...

Page 20: ...nspect torch assemblies and replace if necessary 5 faulty components in the system a return for repair or have qualified technician repair as per service manual C limited output with no control 1 poor...

Page 21: ...ON fast blinking and display shows TRI 1 The operator Turn ON the unit with the torch trigger pressed or broken 2 The unit is now blocked 3 Turn Off the unit and check torch See section SERVICE PIP P...

Page 22: ...t you should get information on approved collection systems from our local representative By applying this European Directive you will improve the environment and human health IN CASE OF MALFUNCTIONS...

Page 23: ...6934900000 23 WIRING DIAGRAM THOR 123...

Page 24: ...Right output inductance Left output inductance Base Input Power cable Flat connection Flat connection Isolator Foot Cover Door Handle Cerniera Side Grid Data Plate Front Panel PCB Pilot Arc Switch Se...

Page 25: ...6934900000 25 TORCH CONSUMABLES VIEW...

Page 26: ...Gouging 9 8241 Stand off Guide 9 8281 Deflector 9 8243 Start Cartridge 9 8213 Torch Head 9 8219 1Torch 6m SL60 7 5253 1Torch 6m SL100 7 5254 601048000L 607380000L 601238000L 607390000L 607400000L 609...

Page 27: ...the Shield Cup with the torch tip in direct contact with the work up to 60 Amps Standoff Cutting The preferred method of cutting metal thicker than 1 4 6 mm and at current levels above 60 Amps Provide...

Page 28: ...d for cutting light gauge sheet metal Gouging A simple method of metal removal by angling the torch to a lead angle of 35 45 and using a gouging tip While maintaining a constant standoff distance this...

Page 29: ...6934900000 29 Info www stelgroup it tel 39 0444 639525...

Reviews: