53
STEL s.r.l.
– Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: [email protected]
http: www.stelgroup.it
MAX 503 IP54 - ATX
COD. 6913000050
1) butt joint
2) T joint
The angle of inclination of the electrode varies according to the passes made: the movement
of the electrode is performed by swinging it and stopping at the sides of the seam so as to
avoid the accumulation of weld material in the centre of the weld.
- Removing slag:
For coated electrodes, it is necessary to remove the slag after each pass. The slag is
removed with a small hammer or, in the case of brittle slag, with a wire brush.
To make the different types of joint correctly in the various positions, it is necessary to practice
under the guidance of an expert.