be picture present if there is no HDMI display connected and the main
display shows picture of component, S-video or component video input.
Command
!ZONEMAINCOMP
X
<CR>
is used to directly switch one of
the component inputs to main zone component output in bypass mode.
Valid values for
X
are 1, 2, 3, 4 or 5. Please note that there will be no
OSD present in bypass mode.
Zone 2 component output
Please note that it is highly recommended to set “Zone Video Output”
setting to “Independent” when using direct switching commands from
serial interface. These commands completely bypass UI and when in
“Independent” mode, UI will never change zone 2 video switching.
Command
!ZONE2SHOW<CR>
is used to directly switch the main
display to zone 2 component output. Please note that there will only be
picture present if there is no HDMI display connected and the main
display shows picture of component, S-video or component video input.
Command
!ZONE2COMP
X
<CR>
is used to directly switch one of the
component inputs to zone 2 component output in bypass mode. Valid
values for
X
are 1, 2, 3, 4 or 5. Please note that there will be no OSD
present in bypass mode.
Direct controlling of trigger outputs
It is possible to control the state of trigger outputs with special serial
control commands. Please note that the commands bypass UI completely.
Commands
!TROOFF(
X
)<CR>
and
!TRODIS(
X
)<CR>
are used to set the
voltage of a trigger output to 0 Volts. Valid values for
X
are 1, 2, 3 or 4.
This command bypasses UI.
Command
!TROON(
X
)<CR>
is used to set the voltage of a trigger output
to 6 Volts. Valid values for
X
are 3 or 4 (trigger outputs 3 and 4 are the
only dual-voltage trigger outputs). This command bypasses UI.
Command
!TROHI(
X
)<CR>
is used to set the voltage of a trigger output
to 12 Volts. Valid values for
X
are 1, 2, 3 or 4. This command bypasses UI.
Command
!TROEN(
X
)<CR>
is used to set the voltage of a trigger output
to configured level (voltage setting from Trigger Output setup). Valid
values for
X
are 1, 2, 3 or 4. This command bypasses UI.
Command
!TRODO(
X
)<CR>
is used to execute the trigger function that
is configured in the Trigger Output setup. This means that if some event
triggers a 5 second pulse in trigger 1, command
!TRODO(1)<CR>
would
cause the trigger output to do the pulse even if the actual event
triggering the trigger never happens. Valid values for
X
are 1, 2, 3 or 4.
This command bypasses UI.