Controlling OSD and OSD menu
There are two On Screen Display menus in the P1 controller. The Installer
menu is intended to be used by the installer and that menu should not
be offered to the end user. The user menu (titled “Menu”) is intended for
the daily use of the user. When using a well designed serial control
interface, it should not be necessary for the user to access the OSD
menu. It is, however, possible to access and use both of these menus by
using the serial interface.
Command
!MENU<CR>
is used to enter the “Installer menu”. This
function should not be available for the user.
Command
!ENTER<CR>
is used to access the user menu (when not in
menu) or to enter/modify a menu item (when inside the menu). In other
words this command does the same as the “Ok” button in the installer IR
remote.
Command
!INFO<CR>
bring the information screen to the OSD display
(when not in menu). The command does the same as the INFO button on
the installer IR remote.
Commands
!DIRU<CR>
,
!DIRD<CR>
,
!DIRL<CR>
,
!DIRR<CR>
and
!BACK<CR>
have the same effect as the similar buttons in the installer IR
remote. Furthermore command
!NUM(X)<CR>
acts as a number keypad
(only useful in the Network Setup menu page).
Please note that there is no way for the serial interface to know whether
the system is in OSD menu or not. In normal operation there should be
no need for the user to access the On Screen Menu when using a
dedicated serial control interface.
Direct controlling of component outputs
It is possible to control the component outputs of the P1 controller
directly using special serial control interface commands. The controlling
allows routing of any component input directly to either one of the
component outputs in bypass mode. Bypass mode means that there is no
On Screen Display possibility. It is also possible to route the main display
with OSD to the outputs, but this is only possible when there is no HDMI
display connected. It is possible to switch component inputs to
components outputs in bypass mode when there is HDMI display
connected.
NOTE:
These commands completely bypass UI controls.
Main zone component output
Command
!ZONEMAINSHOW<CR>
is used to directly switch the main
display to main zone component output. Please note that there will only