![STEINWAY LYNGDORF P1 Manual Download Page 13](http://html.mh-extra.com/html/steinway-lyngdorf/p1/p1_manual_1371469013.webp)
13
STATUS REQUESTS
Command
string
Return string
Description
!PING?
!PONG or nothing if
device is off
This command can be used to
determine whether the device
is on or off
!POWER?
!POWER(X)
Current power status.
1 = main zone is on
2 = zone2 is on
3 = both main zone and zone2
are on
!MUTE?
!MUTEON or !MUTEOFF User mute status
!ZMUTE?
!ZMUTEON or
!ZMUTEOFF
Zone user mute status
!VOL?
!VOL(X)
Current volume level. -799 –
200 (-79.9dB – 20.0dB)
!ZVOL?
!ZVOL(X)
Current zone volume level. -
960 – 200 (-96.0dB – 20.0dB)
!SRC?
!SRC(X)”Source name”
Current sources number and
name, X is number of the
source and source name is
between double quotes
!SRC(X)?
!SRC(X)”Source name”
or nothing if source
does not exist
Given sources number and
name, X is number of the
source and source name is
between double quotes
!SRCS?
!SRCCOUNT(X) followed
by each source
!SRCX”Source name”
Returns the count of all
sources followed by the
numbers and names of each
source.
!TRO(X)?
!TRO(XY)
Current output voltage of given
trigger output.
Possible values for X:
1-6
Possible values for Y:
0 means 0V
1 means 6V
2 means 12V
!TROS?
Each trigger output
Returns the voltage of every