User manual |
Orbit 3100/3300/3500/3400/3600 Camera
6
Picture 1: Connections PSU
NOTE! Remember: do not connect 230V before everything else is completely wired. When
disassembling, remove the power before starting work.
4.1.2
Camera coupling
Before connecting the camera cable, make sure to add a thin layer
Molykote
44 (approx. 1/10 of the
depth of the contact). See picture 2 below for illustration.
Picture 2: 6-pin underwater Connector with recommended level of grease
After the connector is disconnected, rinse thoroughly with Isopropyl alcohol to make sure all sand,
fouling etc. is taken out, and apply a new layer of Molykote 44.
Picture 3: Connecting cable to camera housing