Table 4-1 Preventive Maintenance Checks and Services
Item
Item to
Not Fully Mission
No.
Interval Check/Service
Procedure
Capable If:
11
B/A
Activation Mode
-Select A/L (AIM LO) using
Activation Mode
Selector Switch
the Activation Mode
Selector Switch
and Integrated
Selector Switch.
inoperative with the
Momentary
-Use the Integrated
IR POINT or IR ILLUM
Activation Switch
Momentary Activation
Beam Spot not visible.
Switch and observe the
beam spot on wall through
(NVD necessary).
-Select A/H (AIM HI) and
repeat the activation.
-Repeat for each laser
activation position.
12
B
Boresight
-Confirm that the IR POINT
Alignment
can be zeroed on the weapon
on which it will be mounted.
-Check to make sure that the
IR POINT projects on the
same side of the target as the
laser is mounted and falls within
10.2cm of the bore at 25 meters.
See Paragraph 3.5.
13
B/D/A
LED Status
-Observe green LED is lit
Indicator
when lasing.
14
B/A
Remote Cable
-Insert the remote cable switch
Switch
and activate the laser.
59
Summary of Contents for DBAL-I2
Page 1: ...DUAL BEAM AIMING LASER VISIBLE LASER POINTER IR LASER Technical Manual ...
Page 9: ...CHAPTER 1 GENERAL INFORMATION 8 Figure 1 1 DBAL I2 in Use ...
Page 51: ...Figure 3 14 Laser Borelight 10 meter Zeroing Target 50 ...
Page 55: ...Figure 3 15 Commercial 25 meter Zeroing Target 54 ...
Page 78: ...77 APPENDIX A REPAIR PARTS Figure 1 Repair Parts ...