Aiming floodlight head (Fig. 5.2)
• Undo the grub screws to alter aim.
After altering aim, fix floodlight head
in place with grub screws.
(Fig.
• When aiming the floodlight head,
make sure that water can drain out of
the drainage holes.
(Fig.
5.3)
Aiming sensor unit (S versions only)
• When aiming the sensor unit, make sure
the sensor covers the detection zone.
Adjusting the detection zone (S
versions only)
To rule out inadvertent triggering or tar
get specific danger spots, the detection
zone can be limited with film shrouds.
The film shroud is stuck onto the sensor
unit.
–
Limiting the horizontal detection zone
with filmshroud segments cut to
size.
• When adjusting the detection zone,
select shortest time and daylight
operating mode.
6. Cleaning and
Maintenance
Hazard from electrical power.
Contact between water and live parts
can result in electrical shock, burns or
death.
• Product must not be wetcleaned.
Risk of damage to property!
Using the wrong detergent can damage
the light.
• Make sure detergent does not harm
the surface.
• Clean light with a soft cloth and mild
detergent.
Important note:
the control gear cannot
be replaced.
7. Troubleshooting
Light does not switch ON.
–
Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
–
Break in wiring.
• Check wiring with voltage tester.
–
Short circuit in mains power supply
lead.
• Check connections.
–
Mains switch OFF.
• Switch ON mains switch.
–
Wrong twilight setting selected.
• Reset brightness response
threshold
–
Continued movement within the
detection zone.
• Check detection zone.
–
Light source faulty.
• The light source cannot be
changed. Completely replace light.
Light does not switch OFF.
–
Continued movement within the
detection zone.
• Check detection zone.
• If necessary, limit detection zone.