Ambient temperature:
-20°C to +40°C
–
IP rating:
IP44
–
Protection class:
I
4. Installation
Hazard from electrical power.
Touching live parts can result in electri
cal shock, burns or death.
• Switch OFF power and interrupt
power supply.
• Using a voltage tester, check to make
sure the light is disconnected from
the power supply.
• Make sure power supply remains
interrupted.
Risk of damage to property!
Mixing up connection leads may pro
duce a short circuit.
• Identify connection leads.
• Reconnect connection leads.
Preparing for installation
• Check all components for dam
age. Do not use the product if it is
damaged.
• Select an appropriate site to install
the product.
–
Taking reach into consideration
–
Taking reach and motion detection
into consideration.
–
Vibrationfree.
–
No obstacles in detection zone.
–
Not in explosive atmospheres.
–
Not on normally flammable
surfaces.
–
Do not look into the LED light from
a short distance (<20
cm).
Light distribution curve (Fig. 4.4)
Mounting procedure
• Check to make sure the power sup
ply is switched OFF.
(Fig.
• Mark drill holes.
(Fig. 4.5)
• Drill holes (Ø 8 mm) and fit wall plugs.
(Fig. 4.6)
• Feed connection cable through
bracket and aim floodlight head.
Remember to include extra length of
cable for aiming the floodlight head
later on.
(Fig. 4.7)
• Aim floodlight head and fix in place
with grub screws.
(Fig. 4.8)
• Screw bracket to mounting surface.
(Fig. 4.9)
• Connect power cable to local power
supply.
(Fig. 4.10)
• Switch ON power supply.
(Fig. 4.11)
The light is ready for use. Settings
and detection zone can be changed if
necessary.
➜
"5. Use"
5. Use
Factory settings
–
Time setting: 8 seconds
–
Twilight setting: daylight mode
Time setting (S versions only)
The time (stayON time) can be set
to any period from approx. 8 seconds to
a maximum of 35 minutes. Every move
ment detected reactivates the light.
Twilight setting (S versions only)
The brightness response threshold
(twilight) can be infinitely varied from
approx. 2 to 2,000 lux.
–
= daylight mode (depending on
ambient light level)
–
= nighttime operation (approx.
2 lux)