TROUBLESHOOTING
Unit not warming up
• Not plugged in
• No electrical contact between
heating cylinder and base station
• Electrical contacts on heating
cylinder dirty or soiled with adhesive
• Check power cord
• Insert heating cylinder into
contact slot on base
• Clean electrical contacts on
heating cylinder
Problem
Cause
Solution
Adhesive has stopped
extruding
• Adhesive temperature too low
• Adhesive past shelf life
• Cured adhesive in cartridge tip
• Tightly seal cartridge and
re-heat in base unit
• Allow gun to cool, then install
a new cartridge
• Attempt to clear cartridge tip
Green indicator light
appears immediately after
changing cartridge
• Heating cylinder still hot from
previous use
• Ensure that “cold” cartridge is
heated for at least 12 minutes
BOND STRENGTH OF HiPURformer™ ADHESIVES
Strength Development
10 minutes
1 hour
24 hours
650 psi
1090 psi
1360 psi
600 psi
1130 psi
1480 psi
270 psi
600 psi
900 psi
Maple to Maple
WW30
WW60
MP75
Recommended Applications
E
= Excellent adhesion
G
= Good adhesion
NR
= Not recommended
E
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
E
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
G
E
E
E
E
E
E
E
E
E
E
E
SUBSTRATE
WW30
WW60
MP75
118 psi
478 psi
1016 psi
MP300
G
E
E
E
E
E
E
E
E
E
E
E
MP300
Wood
Steel
Ceramics
Aluminum
ABS
Concrete/Brick
Vinyl
Glass/Marble
Melamine
PVC
Lexan
FRP
8