STEINEL HiPURformer User Manual Download Page 2

TECHNICAL SPECIFICATIONS

1

  feed rod

2

  cartridge cap holder

3

  trigger

4

  power cord

5

  base station with status indicator

6

  cartridge cap

7

  heating cylinder

Voltage: 

120v AC

Output:

 12 watts in standby phase, 200 watts while heating

Heat-up Time:

 10-13 minutes

Working Temperature:

  212-284°F

Maximum Working Time: 

Approximately 20 minutes away from base unit

Cartridge: 

Works with all 

HiPURformer™

 50 gram cartridges

2

1

3

4

5

6

7

2

Summary of Contents for HiPURformer

Page 1: ......

Page 2: ...dicator 6 cartridge cap 7 heating cylinder Voltage 120v AC Output 12 watts in standby phase 200 watts while heating Heat up Time 10 13 minutes Working Temperature 212 284 F Maximum Working Time Approx...

Page 3: ...Read operating instructions thoroughly before using adhesive applicator WARNING Eye and Skin Irritant Potential Skin and Respiratory Sensitizer Caution Contact with heated product may cause thermal b...

Page 4: ...dhesive is removable by heating to 280 F with a hot air gun Bond will soften at approximately 280 F but adhesive will not flow or become liquid DO NOT USE HEAT GUNS WITH FLAMMABLE OBJECTS OR SUBSTRATE...

Page 5: ...sive has reached bonding temperature and is ready to use 5 Always wear gloves Remove tool from base station 6 Unscrew cap store in handle Depress trigger to extrude adhesive Feed rod will advance and...

Page 6: ...ly cured Optimum bond strength is achieved by joining the two contact surfaces immediately after applying adhesive Hardened excess adhesive can easily be removed with a scraper or putty knife soon aft...

Page 7: ...nd permanently void this warranty To obtain warranty service call STEINEL s Customer Service Department in the USA at 1 800 852 4343 or in Canada at 1 604 299 3506 A Customer Service Representative wi...

Page 8: ...to clear cartridge tip Green indicator light appears immediately after changing cartridge Heating cylinder still hot from previous use Ensure that cold cartridge is heated for at least 12 minutes BOND...

Page 9: ...NOTES 9...

Page 10: ...FF 662 8 4 04 LB...