- 12 -
- 13 -
L
Disconnect the power
supply before attempting
any work on the sensor.
L
During installation, the
electric power cable being
connected must not be live.
Therefore, switch off the
power first and use a volt-
age tester to make sure the
wiring is off-circuit.
L
Installing the sensor involves
work on the mains power
supply. This work must
therefore be carried out
professionally in accordance
with the applicable national
wiring regulations and elec-
trical operating conditions
(VDE 0100).
System Components
a
Load module
b
Sensor module
c
Locking mechanism
d
Potentiometer adjustment
e
Kaiser hollow-wall box,
optional
f
Surface-mounting adapter
g
Clamping-type ceiling
adapter
h
Sensor base
i
Assembly / installation
j
Reach setting table
k
Wiring diagram
l
Setting capability via
LiveLink app
Assembly/Installation (see Fig. on page 2)
The sensor is only intended for
concealed, indoor installation in
ceilings. A clamping-type ceiling
adapter or surface-mounting
adapter is not included.
Sensor and load module come
ready assembled and must be
plugged together after fitting
the load module and setting
the reach (IR Quatrro HD Live-
Link). The sensor module must
now be locked in place with the
catch mechanism
c
, using a
screwdriver if necessary.
Accessories:
Kaiser hollow-wall box,
EAN no.: 4007841 000370
Clamping-type ceiling adapter
EAN no.: 4007841 002855
Surface-mounting adapter,
EAN no.: 4007841 000363
Guard cage,
EAN no.: 4007841 003036
Operating Instructions
GB
Dear Customer,
Congratulations on purchasing
your new STEINEL sensor and
thank you for the confidence
you have shown in us. You have
chosen a high-quality product
that has been manufactured,
tested and packed with the
greatest care.
Please familiarise yourself with
these instructions before at-
tempting to install the sensor
because prolonged, reliable and
trouble-free operation will only
be ensured if it is fitted- and
used properly.
We hope your new STEINEL
sensor will bring you lasting
pleasure.
Safety Precautions
How it Works / Basic Function
The infrared and high-frequency
presence detectors from the
Control PRO range control
lighting, e.g. in offices, WCs,
public buildings or at home, in
relation to ambient light level
and the presence of persons.
Modern, high-frequency tech-
nology guarantees that move-
ment is detected absolutely
anywhere irrespective of radiat-
ed temperature.
Sensing movement in two
directions, the DUAL HF Live-
Link sensor is ideal for corridors
in hotels, schools and office
buildings.
The IR Quattro HD LiveLink with
highly advanced lens provides
a square detection zone, as the
typical shape of a room, in
which the smallest of move-
ments are sensed.
Settings are made via app
using the LiveLink Box. The
setting mechanism on the
sensor is used for setting the
IR Quattro HD LiveLink reach.
The sensor is connected to the
LiveLink Box as a control unit
by means of a DALI bus. The
sensor uses the DALI line for
communicating with the Live-
Link Box and for power. The
LiveLink sensors only work in
the LiveLink system.
Setting capabilities by
LiveLink APP:
− Reach setting
− Twilight setting
− Time setting
− Semi- / fully automatic mode
− Constant lighting control
− Interconnecting several
sensors
− Teach mode
− Test mode
− Daytime operation
− IQ mode
− Basic brightness
Detection Zone
A reliable presence detection depends largely on
the number, quality and arrangement of the lens
elements. The IR Quattro HD LiveLink and the
square detection zone covering an area of 64 m
2
has 4800 switching zones
that provide even greater precision. These reaches
can be adjusted to suit specific requirements by
the mechanical reach setting capability. The
square detection zone provides the basis for cre-
ating optimum configurations quickly and easily.
presence
radially
tangentially
tangentially
radially
presence
IR Quattro HD LiveLink
GB
14
12
10
8
6
4
2
0
2
4
6
8
10
12
14