– 12 –
GB Installation instructions
Dear Customer,
Congratulations on purchas-
ing this STEINEL Infrared
Sensor and thank you for
the confidence you have
shown in us. You have cho-
sen a high-quality product
that has been manufac-
tured, tested and packed
with the greatest care.
Please familiarise yourself
with these instructions
before attempting to install
the sensor since prolonged
reliable and trouble-free op-
eration will only be ensured
if it is installed properly.
We hope your new Infrared
Sensor will give you lasting
satisfaction.
System components
1
Security screw
2
Front cover
3
Lens (can be removed
and turned for selecting
the max. basic reach set-
tings of 5 m or 12 m)
4
Light threshold setting
control 2-2000 lux
5
Time setting control
5 sec. - 15 min.
6
Clip (housing can be
flipped up for assembly
and connection to mains
power supply)
Technical specifications
Dimensions (H × W × D):
120 × 78 × 55 mm
Output:
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
Connection:
230-240 V, 50 Hz
Detection angle:
180° horizontal, 90° vertical
Sensor reach:
basic setting 1: 5 m max.
basic setting 2: 12 m max. (factory setting)
+ precision adjustment from 1-12 m by means
of clip-on shrouds
Time setting:
5 sec. - 15 min. (factory setting: 5 sec.)
Light threshold:
2-2000 lux (factory setting: 2000 lux)
Enclosure:
IP 54
Temperature range:
-20°C to +50°C
1000 W
1000 W
500 VA
406 VA
406 VA
1000 VA
16 W
64 W
64 W
132 μF
Summary of Contents for 057664