STEINDORFF

®

 

1.

 

UNPACKING AND PREPARATION 
 
1.1.

 

Unpacking 

When unpacking the equipment, verify that all parts specified on the delivery note are present. Retain 
the original packaging for storage of the microscope in longer periods of non-use or for return to the 
manufacturer. Always keep the microscope in a clean, dry, and dust free environment. 
 

1.2.

 

Handling 

Always use two hands to carry your microscope. Always ensure that all microscope components 
(eyepieces, cameras, adaptors, stage plates etc.) are secured tightly or otherwise removed before 
transporting. NEVER CARRY THE MICROSCOPE UPSIDE DOWN IN ORDER TO PREVENT 
THE UNIT FROM DROPPING or the ocular components from falling out of alignments. Set up the 
microscope on a stable worktable with solid and smooth tabletop. DO NOT TOUCH OPTICAL 
SURFACES. THIS MAY AFFECT IMAGE QUALITY. 
 

1.3.

 

Storage 

 

Ensure light intensity switch is turned down to the lowest setting and the switch on the base is 
turned off. 

 

Store your microscope with a protective dust cover in a low humidity environment. 

 

Keep all of your eyepieces, objectives and other accessories in place during storage. 

 

2.

 

DESCRIPTION 
 
2.1.

 

Specifications 

Viewing Head 

Siedentopf Binocular or Trinocular head, 30° inclined and 360° rotatable, Interpupillary 
adjustment of 48mm-75mm 

Eyepiece 

High eyepoint WF 10x/22mm with diopter adjustable 

Nosepiece 

Reversed, quadruple or quintuple 

Objectives 

Plan Finite: 

(Models: NYMCS-3007 & NYMCS-3009) 

4x

/0.1 160/0.17, 

10x

/0.25 160/0.17, 

40xR

/0.65 160/0.17, 

100xR

/1.25 oil 160/0.17 

  

HC Infinity Plan: 

(Models: NYMCS-3007HC & NYMCS-3009HC) 

4x

/0.10 ∞/0.17, 

10x

/0.25 ∞/0.17, 

20x

/0.40 ∞/0.17, 

40xR

/0.65 ∞/0.17, 

100xR

/1.25 ∞/0.17 

Focusing System 

Low position coaxial coarse and fine focus adjustment knobs, 37.7mm per coarse rotation, 
0.1mm per fine rotation, fine focus graduation of 1um, calibration 0.002mm 

Stage 

216mm x 150mm built-in double layer mechanical stage, Graphite surface, rounded edges, 
Non-extending rack, Cross travel range of 55mm x 75mm, Verniers for X/Y coordinates 

Condenser 

1.25 Abbe condenser with iris diaphragm position guide markings for different objectives. 

Illumination 

Built-in Köhler illumination with field diaphragm, 5w LED for optimum illumination 

Imaging 

Trinocular head 50/50 light splitting ratio 

Optional Accessory 

0.5x C-Mount, 1x C-Mount (not included) 

Summary of Contents for S-3000 Series

Page 1: ...STEINDORFF S 3000 LED Biological Microscope Series Instruction Manual...

Page 2: ...ment Ring Attachment Notch Specimen Holder Aperture Diaphragm Lever Condenser Filter Field Diaphragm Ring Binocular Head Head Clamping Screw Body Reversed Nosepiece Objective Specimen Stage Condenser...

Page 3: ...2 STEINDORFF Handle Power Input Fuse Power Switch Condenser Focus Knob Coarse Focus Knob Fine Focus Knob Tension Adjustment Ring...

Page 4: ...of your eyepieces objectives and other accessories in place during storage 2 DESCRIPTION 2 1 Specifications Viewing Head Siedentopf Binocular or Trinocular head 30 inclined and 360 rotatable Interpupi...

Page 5: ...djustment on both eyepieces for the compensation of defective vision with diopter scales to facilitate finding the correct setting Parfocality of focus is assured by independent diopter adjustment on...

Page 6: ...om of the stand to protect the focusing parts please see picture above 1 Mount the binocular or trinocular head onto the body of the microscope and tighten the head clamping screw 2 Screw up the objec...

Page 7: ...6 STEINDORFF Eyepieces 3 Binocular Head Trinocular Head CCD Adapter 7 Notch Objective s Condenser s 1 6 2 4 5 Security Screws...

Page 8: ...y slightly toward or away from one another to adjust the distance between the tubes to your individual interpupillary distance The adjustment of the interpupillary distance is correct when you see onl...

Page 9: ...on that s convenient for your observation When the reticule is in focus do not move the diopter ring afterwards to keep the reticule in focus Use the same eye to stare at the specimen turn the focus k...

Page 10: ...iew See Figure D Carefully adjust the sub stage condenser iris diaphragm learn to adjust the contrast to optimize your image without introducing artifacts and without losing detail The whole point to...

Page 11: ...of the objective provides better image resolution and contrast and also increases the depth of focus Since the contrast of microscope specimens is ordinarily low setting the condenser aperture iris d...

Page 12: ...arkfield Observation There are two kinds of darkfield condenser available one darkfield dry NA 1 25 one darkfield oil NA 1 25 1 36 Replace the condenser with the darkfield condenser as needed If darkf...

Page 13: ...agm is not properly centered Center it using condenser centering screws Field iris diaphragm is stopped down too far Open it to an optimum stop position Dirt dust on objective eyepieces condenser or l...

Page 14: ...ot match that of the other Interpupillary distance is incorrect Adjust interpupillary distance Incorrect diopter adjustment Adjust diopter Your view is not accustomed to microscope observation Try loo...

Reviews: