Storage
As soon as the outside temperature permanently falls below +5 °C, the pump should be stored away for
the winter to prevent damage through ice formation (frost bursts).
Permanently installed water pipes do not necessarily have to be deinstalled. If the
location of the pump is protected against heavy soiling and strong weather influences, it
is sufficient to drain the water from the pump and the water pipes.
Winter storage
1. Pull the power plug of the pump
4
.
2. Close the shut-off valves or block the water flow to the pool lines.
3. Uninstall the pool lines and drain them.
4. Remove the drain screws
12
on the pump housing and completely empty the pump.
5. Screw the drain screws into the pump housing.
6. Thoroughly clean the device (see section "Cleaning").
7. Let the device dry completely after cleaning.
8. Store the device in a dry and frost-free location (>= +5 °C) without direct sunlight.
The device is stored.
Troubleshooting
Problem
Possible cause
Remedy
Air bubbles escape from the
injection nozzle or the pump emits
unusual noises.
The pump is sucking in air.
Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
with more water if necessary until the
pool water covers the suction line
connection by approx. 2.5 - 5 cm (1 to 2
in).
The water level in the pool is too
low.
Raise the water level in the pool.
The prefilter basket (if present)
is clogged.
Empty the prefilter basket.
The suction line is out of place
or clogged.
Clean the suction line.
The pump is not running.
The pump has no power.
Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
The external timer is set.
Check the running times on the external
timer.
The pump is defective.
Contact customer service.
If the problem cannot be solved, contact the customer service listed on the last page.
26
Summary of Contents for SPS 100-1
Page 2: ......
Page 3: ...1 2 3 6 5 7 8 4 9 SPS 100 1 11 12 10 13 3 de...
Page 16: ...Ersatzteile 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 16...
Page 28: ...Spare parts 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 28...
Page 42: ...Pi ces de rechange 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 42...
Page 55: ...Pezzi di ricambio 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 55 it...
Page 69: ...Piezas de repuesto 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 69 es...
Page 82: ...N hradn d ly 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 82...
Page 95: ...P talkatr szek 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 95 hu...
Page 107: ...Nadomestni deli 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 107 sl...
Page 120: ...N hradn diely 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 120...
Page 133: ...Cz ci zamienne 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 133 pl...
Page 146: ...Piese de schimb 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 146...
Page 158: ...Rezervni dijelovi 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 158...
Page 160: ...1 2 3 O 79 4 5 O 54 6 2x 7 O 45 8 INTEX 040933 9 INTEX 040934 10 11 12 13 160...
Page 162: ...35 C 0 5 162...
Page 163: ...16A 30 mA RCD 163 bg...
Page 164: ...164...
Page 165: ...2 24 3 5 165 bg...
Page 167: ...1 2 3 4 PH1 INTEX 1 INTEX INTEX 2 INTEX A 1 2 1 2 2 11 3 4 5 6 3 4 167 bg...
Page 168: ...1 2 5 5 2 3 4 5 1 2 2 3 11 4 5 6 7 168...
Page 169: ...5 C 1 4 2 3 4 12 5 6 7 8 5 C 169 bg...
Page 172: ...1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 172...
Page 174: ...174...
Page 185: ...Yedek par alar 1 A A 1 2 3 4 5 12 13 11 10 7 8 14 SPS 100 1 6 9 185 tr...