Testing the residual current device
1. Connect the RCD adapter
C
to the electrical supply that has been prepared at the installation
site.
2. Press the RESET button
12
.
The LED
11
lights up. The heat pump is supplied with electricity and is in the Standby mode.
3. Press the TEST button
13
.
The LED
11
lights up. The heat pump is disconnected from the electricity and the Display
14
goes out.
4. Press the RESET button
12
.
The LED
11
lights up. The heat pump is supplied with electricity and is in the Standby mode.
The residual current device of the RCD adapter has now been tested successfully.
Activating the heating
In the Operate mode, the temperature can be set between 15 and 35 °C. The initial value set for
the water temperature is 27 °C.
Activating the Operate mode
1. Press the RESET button
12
.
The LED
11
lights up. The heat pump is supplied with electricity and is in the Standby mode.
2. Press the On/Off button
15
.
The heat pump
1
is in the Operate mode and the display
14
shows the current water
temperature in °C.
Setting the desired water temperature
1. Press the Up
16
or Down
17
button repeatedly.
The display
14
shows the desired water temperature in °C.
The heat pump will not run if the desired set water temperature is below the current,
measured water temperature.
Displaying or setting parameters
The heat pump has 11 parameters which can be shown or set via the display
D
(see
“Parameters”).
Displaying the parameters
1. Press and hold the SET button
18
for 5 seconds while the heat pump is in the Operate mode.
The display
14
shows “A”.
2. Press the Up
16
or Down
17
button repeatedly.
The display
14
shows the selected parameter (A, B, C, 1-8; see “Parameters”).
3. Press the SET button
18
to select the required parameter.
The value of the selected parameter blinks on the display
14
.
Setting the parameters
1. Press the Up
16
or Down
17
button repeatedly.
The desired value of the selected parameter blinks on the display
14
.
2. Press the SET button
18
.
The desired value of the selected parameter is now set.
41