Parameters
Display range
B
Current water temperature at the outlet
-19 °C - +99 °C
-
C
Current temperature of the heat exchanger
-19 °C - +99 °C
-
The heat pump has eight configurable parameters:
Parameters
Setting range
Default setting
1
Desired water temperature
15 °C - 35 °C
27 °C
2
Temperature difference for a restart
1 °C - 10 °C
2 °C
3
Temperature protection at outlet
30 °C - 80 °C
47 °C
4
Automatic restart
0 - 1
1
5
Duration of the automatic defrosting feature
10 min - 90 min
40 min
6
Temperature setting for the automatic defrosting
feature
-30 °C - 0 °C
0 °C
7
Temperature setting for stopping the automatic
defrosting
1 °C - 30 °C
2 °C
8
Control timer for stopping the automatic defrosting
10 min - 40 min
30 min
Operation
CAUTION!
Risk of injury!
A damaged device or damaged accessories can lead to injuries.
- Check the device and the accessories (see the chapter on “Points to
check”).
NOTE!
Risk of damage due to blockage of the air current!
Reduced or blocked ventilation of the heat pump can lead to insufficient
removal of heat or moisture. This can cause mould to form or overheating of
the finned heat exchanger.
- Clean the grille in front of the fan blade and the fins of the heat exchanger
regularly and ensure that debris such as leaves or the like do not enter the
inner part of the heat exchanger.
- Ensure that the grille on the heat exchanger is never covered over and air
can flow freely through the device.
RCD adapter
The RCD adapter
C
consists of an earth-contact plug and a residual current device. The earth-
contact plug must be connected to a suitable power socket with a protective earth conductor. The
residual current device disconnects the heat pump from the electricity as soon as any unexpected
currents which are hazardous for humans flow via the heat pump (e.g. body contact via
electrically conductive parts of the housing).