4. 

Cut a length of tube approximately 200mm long and connect one end to the mains 

               connection shut off valve and the other end to the inlet of the pressure limitng valve – 

               please ensure you check the flow direction is correct, otherwise water flow will be 

               restricted.

5. 

Cut the next length of tubing to the required length to reach from the outflow of the 

               pressure limiting valve to the inlet of the filter housing, leaving enough flex so it is not 

               rigid tight, and so it can be tucked neatly out of the way.  Please ensure you have 

               connected to the IN side of the filter housing.   

6. 

Use the remaining tube to connect from the outlet of the housing to the faucet, cut to 

               length if required

Summary of Contents for Triple Undersink

Page 1: ......

Page 2: ...iltration system has not been used for 2 or more days you will need to flush 5 to 10 litres of water through the system before using the water If the unit is to be left unused for more than 2 days the water supply valve must be turned off Slower flow rate gives longer contact times for better contaminant reduction To maintain a high level of performance and protection provided by the STEFANI water...

Page 3: ...ITH AN EXISTING MIXER TAP OR DISHWASHER TAP AND LOCATION SELECTION INSTALLATION INSTRUCTIONS STEP 2 6 PURIFICATION SYSTEM ASSEMBLY INSTALLATION INSTRUCTIONS STEP 3 8 MOUNTING THE FAUCET FINISHED INSTALLATION 9 REPLACING FILTER CARTRIDGE 9 WARRNATY 11 STEFANI WATEL FILTER CARTRIDGE 11 ...

Page 4: ...t 1 4 1 4 QC 50PSI Pressure Limiting Valve 1 5 1 4 OD PE White Tube 1 5 meters 1 6 Faucet and 1 4 tube union connector 1 7 Faucet Fittings Small Rubber Washer Chrome Cover Plate Large Rubber Washer Round Plate Locking Washer Brass 1 8 Teflon Thread Seal Tape 1 2 x 120 1 9 Screw for Manifold Bracket Phillip Head 4 pcs bag 1 10 1 1 11 1 12 Wrench with depth gauge washer Filters 1 Carbon Block filter...

Page 5: ...e flex hose and the mains water supply 6 Ensure the valve is in the OFF position and turn the mains water on to check for any leaks on this part of the installation If no leaks occur turn the mains water back off until ready to test the final installation If leaks occur remove the mains shut off valve and re tape and refit and recheck for leaks INSTALLATION INSTRUCTIONS STEP 1 The Triple Undersink...

Page 6: ...tions attached to the wrench INSTALLATION INSTRUCTIONS STEP 2 CAUTION Please use this metal piece as a guage to varify if the IN Metal piece fits here Must be on IN side Housing side Important notes on1 4 inch tubing When cutting the inch tubing ensure the cuts are square and clean other wise leaking may occur When connecting the tube to the quick connect system ensure you push the tube all the way...

Page 7: ...r flow will be restricted 5 Cut the next length of tubing to the required length to reach from the outflow of the pressure limiting valve to the inlet of the filter housing leaving enough flex so it is not rigid tight and so it can be tucked neatly out of the way Please ensure you have connected to the IN side of the filter housing 6 Use the remaining tube to connect from the outlet of the housing...

Page 8: ... the desired direction 4 Insert the inch connection piece onto the shaft of the faucet and push in until it fully stops pull slightly to seal the connection 5 Insert the inch tubing from the outlet of the filter housing into the connection piece until it fully stops pull slightly to seal the connection 6 Turn on the water supply and allow the water to run for 10 minutes before enjoying fresh water...

Page 9: ...r Carbon filter Stage 2 in centre of housing 102 Carbon Block filter Stage 3 next to housing outlet 1 Turn off water supply to filter system this can be achieved by turning the ball valve of the mains connection valve as shown in the installation drawings clockwise until it will not turn any further Test water supply is off by opening the faucet to check if water has stopped running If water does ...

Page 10: ...nutes to expel air bubbles trapped in the system during the filter cartridge change Water may appear milky These are only tiny air bubbles and some contaminants being expelled from the new filter cartridge Flush water until it runs clear LOW NO MAINTENANCE REQUIRED The only requirement is changing the filter cartridge Maximum filter cartridge life expectancy is 6 8 months The life and performance ...

Page 11: ...prove performance and protection when used in other brands of water filtration systems Suitable for use in all systems using standard length 248 250mm filter cartridges Product code Barcode Description STEFANI SEDIMENT REDUCTION CARTRIDGES For removal of sediment dirt rust turbidity algae and all other particulate contaminants PP 0510 9319652006720 5 micron nominal PPG 0510 9319652006775 5 micron ...

Page 12: ...720 Please check the Water Filter Cartridge Guide on page 11 for other suitable fillters for this system Register online at www stefani com au for a filter change reminder by email A filter change reminder fridge magnet has been supplied for your convenience Stefani Australasia PTY LTD 55 Banksia Road Welshpool Western Australia 6106 Tel 08 9350 6178 Email stefani stefani com au www stefani com au...