Page 3 of 3
939501454 Rev A
2.
1c.
BOX HALF ASSEMBLY
BASE
FACEPLATE (AT&T)
FACEPLATE (AMP)
BOX HALF
WINDOW
TO BE INSERTED IN UNUSED
OPENING AS REQUIRED
BOX HALF
ASSEMBLY
Cable connect box assembled under
bottom of desk or worksurface
1c.
Secure base to back side of box half
assembly with (2) screws. Locate box half
assembly to a desired location and use as template
to drill (2) 5/32” dia. holes 3/4” deep into the bottom
of worksurface. Attach with (2) screws. Proceed to
Step 2.
NOTE:
For steel worksurfaces, drill holes into hat
section braces.
2.
Install cable windows as required. (windows
may be broken in half for a smaller dia. cable
passage). Position box half and desired face plate
and secure with required screws.
NOTE:
Some prewiring may be required!
SCREW 10 X 7/8”
WORKSURFACE HOLES
5/32” X 3/4” DEEP
NOTE: MARK OR TAPE
DRILL FOR 3/4” DEPTH
8-32 X 3/8” BLUNT
NOSE SELF
TAPPING SCREW