Instructions for the installer
50
3.5.2 Type of power supply
It is possible to obtain different connections according to the voltage, simply by moving the
unconnected cable ends on the terminal board as shown in the following diagrams.
60x60 / 60x90 / 90x60 OVEN
ORIGINAL CONNECTION
SET BY MANUFACTURER
.
60x90 OVEN
N
OT APPLICABLE FOR
A
USTRALIA
.
3.5.3 Replacing the electric cable
To replace the electric cable, it is necessary to access the terminal board. It is located on the back
of the appliance, at the top left, as shown in the figure.
To replace the cable, proceed as follows:
•
open the terminal board box;
•
unscrew the screw A that locks the cable;
•
loosen the screw contacts and replace the cable
with one of the same length and conforming to
current regulations;
•
the "yellow-green" earth wire must be connected to
the terminal
and must be approximately 20 mm
longer than the line cables;
•
the neutral "blue" wire must be connected to the
terminal marked with the letter N;
•
the line wire must be connected to the terminal
marked with the letter L.
3.6
Electric power table
OVEN TYPE
NUMBER OF OVENS
TOTAL POWER
Max Watt
60 x 60
1
3025
60 x 90
2
5800
90 x 60
1
3600