26
TABLE INSERT ADJUSTMENT
F
ig
. 32
1. The table insert (A) must always be level with the saw
table (B).
2. Place a straight edge across the front and rear of the
table insert. Check that the insert is perfectly level with
the saw table.
3. To level the table insert, turn the one or more adjusting
set screws (C) as needed and recheck.
5. The table insert is equipped with a finger hole (D) for
easy removal.
SEE FIG. 32
MITER GAUGE ADJUSTMENT
F
ig
. 33
1. The miter gauge has adjustable positive stops at 0-
degree and 45-degrees or it can be manually set at
any angle between 60-degrees.
2. To rotate miter gauge body (A), loosen knob (B) and
pull out plunger (C) and rotate miter gauge body to
desired angle and tighten knob.
3. To rotate to the next positive stop, pull plunger (C) out,
rotate miter gauge body then push plunger back in and
continue rotating miter gauge body until it stops
Against next positive stop.
SEE FIG 33
A
B
C
D
C