ELECTRICAL REQUIREMENTS
The motor in this machine is designed for 230 Volt 3
phase use. Power connections for this must be made
at the switch. For connections refer to wiring photo
Fig. B.
On your incoming power line:
1.
The White Lead connects to terminal L1
2.
The Black Lead connects to terminal L2
3.
The Red Lead connects to terminal L3
4. The Ground Line connects to the grounding
terminal
After making these connections, turn the saw on to
make sure that the arbor is turning towards the opera-
tor. If the arbor rotates in the proper direction the
connection is complete. If the arbor rotates away from
the operator, switch any 2 lines with one another to
change direction of rotation.
Notice:
Some Table Saws will be equipped with a junc-
tion box located near the base of the saw. If this is the
case with your model saw, all power connections will be
made in the junction box instead of at the switch. The
junction box will have terminals for L1, L2, L3, and
Ground. Following the steps above, connect the wires
to their proper terminals.
USE THIS SETUP FOR MODEL NUMBER 35635 ONLY
TO PREVENT
electrical shock, follow all electrical and
safety codes, including the National Electrical Code
(NEC) and the Occupational Safety and Health
Regulations (OSHA). All electrical connections and
wiring should be made by qualified personnel only.
TO REDUCE
the risk of electrical shock,
DO NOT
use
machine outdoors.
DO NOT
expose to rain or mois-
ture. Store indoors in a dry area.
DO NOT
connect the machine to the power source
before you have completed the set up process.
DO NOT
connect the machine to the power source until
instructed to do so.
RED LEAD TO
L3 TERMINAL
GROUND WIRE
TO GROUNDING
TERMINAL
WHITE LEAD TO
L1 TERMINAL
BLACK LEAD TO
L2 TERMINAL
Fig. B