Pub. No. 200-A

- 3 -

^

^

MENU

^^

^ ^

1

2

®

Electrical Installation Instructions

Figure 3 - Typical Installation

Models: TSG-15

The TSC Control 

MUST

 be 

installed inside (Required).

Inside Installation

Control should be mounted 

four feet from the floor. Select a 

location convenient to the 

bather but not in a direct line of 

Shower or Body sprays and not 

directly above the steam head.

Summary of Contents for TSG-15

Page 1: ...d Fuse circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Genera...

Page 2: ...g insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the amount of ste...

Page 3: ...cal Installation Models TSG 15 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Page 4: ...al Block Optional Auto Drain Valve Water Level Probe Fuse Block WH GY GN BL BL BN BN BK BK Ground Lug RH2_L1 RH3_L1 RH4_L1 RH1_L1 RH2_L2 RH3_L2 RH4_L2 RH1_L2 F1 F2 Heating Elements Sensor L1 L2 GND Field Connections P1 P2 RD RD RD RD RD RD RD BK BK BK RD BK BK BK BK BK 15VDC 15VDC Out Tank Frame GND Processor Board P1 P2 P3 P4 0 5 AMP Wiring Diagram Model TSG 15 TSG 15 550 15 240 208 1 1 63 72 4 4...

Page 5: ...ocations include Vanity Closets or Basement near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam ...

Page 6: ...the previously installed water line The valve must be kept in an open position during normal operation In areas where high water pressure may be a problem a water hammer arrestor or a pressure regulator should be installed Complete water supply by connecting 3 8 copper tubing from the valve to the water inlet compres sion fitting Refer to Figure 2 IMPORTANT Do NOT use a saddle valve or piercing ty...

Page 7: ...d by local codes WARNING If installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The stea...

Page 8: ...ION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Access Requirements Model TSG 15 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actu...