IMPORTANT:

Install top first

MUST 

be vertical

After inserting the top, 

snap in the bottom.

Cover 

Plate

Aromatherapy 

Reservoir

Back Plate

O-Ring MUST 

seal to inside of 

the Back Plate.

Center 

Hub

¾" NPT

(Brass Pipe)

Must use sealant 

tape.

Apply silicone around 

the back edge of the 

Back Plate to seal and 

prevent movement.

" Hex Key

Hole

Apply silicone 

around the steam 

pipe to form a 

water-tight seal.

½

Figure 3 - Steamhead Installation 

Figure 3a - Center Hub Installation

®

Steam Generator

Water Level Probe

Hot or Cold

Incoming Water

Supply

Shutoff

Valve

Union

(Required)

Free-Flowing

Steam Line

Pressure Safety Valve

Connect to Indirect Waste

or As Required by Local Codes.

IMPORTANT:

 Install

steamhead 18" above

the shower floor or 6"

above the rim of the

bathtub.

Optional Auto Drain Valve
Connect to Indirect Waste

or As Required by Local Codes.

Water Solenoid Valve

®

Plumbing Installation Instructions

3. 

Steam Generator Installation

The Steam Generator should be mounted in a location convenient 
for hook-up and service by the plumber and electrician.

CAUTION: The steam generator is designed to be used ONLY in 
an upright and level position, to do otherwise would damage the 
unit and void the warranty.

a) The Steam Generator can be mounted to a wall or set 

on the floor. However, the unit must be secured. To 
secure the unit to a vertical wall, loosen the two screws 
holding the electrical access cover, remove cover (see 
Figure 1). Located inside the cabinet near the top left 
and right corners are mounting holes. Place top cover 
back and secure.

b) Connect the 3/8" water supply, described in Section 2, to 

the Steam Generator by first soldering a 3/8" valve into 
the previously installed water line. The valve must be 
kept in an open position during normal operation. In 
areas where high water pressure may be a problem a 
water hammer arrestor or a pressure regulator should 
be installed. Complete water supply by connecting 3/8" 
copper tubing from the valve to the water inlet compres-
sion fitting. Refer to Figure 2.

    IMPORTANT: Do NOT use a “saddle valve” or piercing 

type valve for water connection.

c) Connect the steam line from rough-in location described 

in Section 2 to the ¾" nipple on the Steam Generator 
using a union.

d) In the shower, place the center of the escutcheon 

onto the steam pipe and screw the steamhead into 
place. Care must be taken not to scratch the 
steamhead or escutcheon with wrench. After the 
plumbing connections are complete the electrician 
may finish wiring the unit.

Figure 2 - Plumbing Diagram 

Installation Instructions

3199 Series Steamhead Installation Instructions

Models: TSG-15

Figure 3

1. Make sure the ¾" nipple protrudes beyond the tile 
  approximately ½". (See Figure 3)

2. Wrap the nipple with pipe sealant tape.

3. Put a bead of silicone around the outer edge of the Back   
    Plate (see Figure 3) and center the Back Plate over the pipe   
    in an upright position. While holding it in place, screw the    
    Center Hub onto the nipple, using a 

" hex key to tighten.

4. The Center Hub MUST be aligned with the four walls in the  
  vertical and horizontal position (See Figure 3a). Make sure  
  the steamhead O-ring is fully seated into the Back Plate. 

  If the nipple is sticking out too far the O-ring will not make 
  a proper seal and the nipple must be adjusted.

5. Apply a small amount of silicone at the back center point 
    of  the Cover Plate.This will aid in preventing movement      
    of this plate. (See Figure 3a)

6. Place the Cover Plate over the Center Hub. This is 
  accomplished by first hooking the top and then snapping 
  the bottom into place.

7. Adjust the Back Plate and Cover Plate to line up 
    squarely, and clean excess silicone with rubbing alcohol.

Summary of Contents for TSG-15

Page 1: ...d Fuse circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Genera...

Page 2: ...g insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the amount of ste...

Page 3: ...cal Installation Models TSG 15 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Page 4: ...al Block Optional Auto Drain Valve Water Level Probe Fuse Block WH GY GN BL BL BN BN BK BK Ground Lug RH2_L1 RH3_L1 RH4_L1 RH1_L1 RH2_L2 RH3_L2 RH4_L2 RH1_L2 F1 F2 Heating Elements Sensor L1 L2 GND Field Connections P1 P2 RD RD RD RD RD RD RD BK BK BK RD BK BK BK BK BK 15VDC 15VDC Out Tank Frame GND Processor Board P1 P2 P3 P4 0 5 AMP Wiring Diagram Model TSG 15 TSG 15 550 15 240 208 1 1 63 72 4 4...

Page 5: ...ocations include Vanity Closets or Basement near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam ...

Page 6: ...the previously installed water line The valve must be kept in an open position during normal operation In areas where high water pressure may be a problem a water hammer arrestor or a pressure regulator should be installed Complete water supply by connecting 3 8 copper tubing from the valve to the water inlet compres sion fitting Refer to Figure 2 IMPORTANT Do NOT use a saddle valve or piercing ty...

Page 7: ...d by local codes WARNING If installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The stea...

Page 8: ...ION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Access Requirements Model TSG 15 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actu...

Reviews: