WARNING 

HOLD THIS FITTING SECURELY WITH A PIPE 
WRENCH WHILE MAKING A PLUMBING 
CONNECTION TO THE WATER INLET IN ORDER 
TO PREVENT INTERNAL DAMAGE TO THE WATER 
SOLENOID VALVE. 

009-1054 

SER 

NO. 

NO. 

SIZE 

IN. 

MODEL

 

SET

 

PSIG 

CAP

 

LBS/HR 

ELDERL

Y

 PERSONS, PREGNANT

 WOMEN OR 

THOSE 

SUFFERING FROM HEAR

T

 DISEASE, HIGH BLOOD 

PRESSURE, DIABETES OR NOT

 IN GOOD HEAL

TH MUST

 

NOT

 USE 

THIS DEVICE UNLESS DIRECTED BY

 PHYSICIAN. 

ALSO STEAMBA

THINGSHOULD BE 

A

VOIDED WHILE 

INT

OXICA

TED. 

009-2006 

W

ARNING 

CAUTION: Shut off Main Power 

Switch Before Opening Door

Heating Element Located Inside. 

009-3019 

US 

® 

 

LISTED 995C 

STEAMBATH GENERATOR 

MODEL NO. 

SERIAL NO. 

HEATER LOAD 

VOLTS PH 

MAX 

AMPS 

kW 

CONTROL CIRCUIT 

VOLTS 

AMPS 

50/60 HZ 

SERVICE BY AUTHORIZED PERSONNEL ONLY 

A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ 

IMPORTANT: 

INSTALL WITH ARROWS POINTING UP 
WARNING:  
Unit must be installed 
INDOORS, in a DRY, NON-FREEZING 
location and with arrows pointing up. 
Service by authrorized personnel only. 

NOTE:  Read all instructions before installation 
CAUTION: To prevent internal damage hold all fittings 
securely while making plumbing connections. 
NOTE: See Wiring Diagram on reverse side of cover. 
CAUTION:  Turn off electric before removing cover. 

NOTE:  This is NOT intended to be used for space 
heating purposes. 

009-1081 

Mounting Holes 

16" 

1¾" 

6¼" 

8¾" 

9

15½" 

3

5

/

16

  

2¾" 

1

¾" Steam Outlet 

Water Inlet 

"  

Compression Fitting 

¾" Safety Relief Valve 

½" Capped Drain Line 
for Optional Auto Drain 

1¼" 

*

17½" 

Knockouts for 

Control Cables 

Top of Access 

Panel 

Access Panel 

*

6½" 

*Add ¼" to the dimension for the louvers 

Front Access 

Front Side View 

Top View 

Back View 

Specifications

02/09

Pub. No. 213-A

Dimensional Drawing

Model: TSG-10

- 2 - 

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: 315 W. Pondera St., Suite F, Lancaster, CA 93534 • Tel: 800-355-6478 • Fax: 661-940-1617 

®

Summary of Contents for TSG-10

Page 1: ...ment near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam line and safety valve reach a temperatu...

Page 2: ...f the escutcheon onto the steam pipe and screw the steamhead into place Care must be taken not to scratch the steamhead or escutcheon with wrench After the plumbing connections are complete the electrician may finish wiring the unit Figure 2 Plumbing Diagram Installation Instructions Models TSG 7 and TSG 10 02 09 Pub No 203 A 2 Apply a small amount of silicone to prevent movement Apply a small amo...

Page 3: ...f installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The steam outlet pipe should be pi...

Page 4: ...eam Generator CAUTION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actual Cu Ft capaci...

Page 5: ...se circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Generator ...

Page 6: ...Before starting insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the...

Page 7: ...nstallation Models TSG 7 and TSG 10 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Page 8: ...MP Wiring Diagram Models TSG 7 and TSG 10 L1 L2 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse TSG 7 220 7 5 240 208 1 1 31 36 8 8 40 50 Specification Chart TSG 10 375 10 240 208 1 1 42 48 6 6 60 60 1 2 3 4 5 6 7 8 Dip Switch Settings for Multiple Steam Generators on Processor Board Generator 1 1 and 2 up Generator 2 1 down and 2 up Generator 3 1 up and 2 ...

Page 9: ...Steam Generators can be typically mounted within 25 ft of the bathing area Steam Generators should be accessible for service Do not install in attic Do not install generators outside in a moist humid area or in an area where parts may freeze or corrode Steamhead to be mounted 18 above floor or 6 above rim of tub and as far from the seating area as possible Rough in Notes Access 28 L x 18 W x 20 H ...

Page 10: ...OINTING UP WARNING Unit must be installed INDOORS in a DRY NON FREEZING location and with arrows pointing up Service by authrorized personnel only NOTE Read all instructions before installation CAUTION To prevent internal damage hold all fittings securely while making plumbing connections NOTE See Wiring Diagram on reverse side of cover CAUTION Turn off electric before removing cover NOTE This is ...

Reviews: