background image

Specifications

Features

5-year parts warranty - 2-year labor warranty

Generator typically can be installed up to 25 ft. from the 
bathing area

Diagnostic LED Displays 

Stainless Steel Construction

Solid-State Circuitry

Codes/Standards

UL 499

UL/CUL Listed

Required Equipment

TSC Control

Required Electrical Service

Dedicated circuit required: See Specification Chart for proper 
electrical requirements

Product Information

Water Supply - 

" Compression Fitting

Steam Line - ¾" Brass BPT male thread

Pressure Relief Valve - ¾" NPT female thread

Drain Line - Capped ½"  Brass NPT male thread 

Generator

Weight - 40 lbs.

Installation Notes

Steam Generators can be typically mounted within 25 ft. of 
the bathing area.

Steam Generators should be accessible for service.

Do not install in attic.

Do not install generators outside, in a moist, humid area or 
in an area where parts may freeze or corrode.

Steamhead to be mounted 18" above floor or 6" above rim 
of tub and as far from the seating area as possible.

Rough-in Notes

Access: 28" L x 18" W x 20" H (35" L with Auto Drain)

02/09

Pub. No. 213-A

Steam Generator

TSG-10

Model: TSG-10

- 1 - 

*Refer to sizing guidelines to accurately determine the proper size generator for the installation.

Steam Generator Specification Chart

10

375

240/1/42
208/1/48

6
6

60
60

Model

Number

Product

Number

KW

Rating

Max. Cu. Ft.

Range*

Volts/Phase/

Max. Amps

Wire Size 90°C

Copper AWG

Line

Fuse

17½" x 6½" x

15½"

Dimensions

L x W x H

TSG-10

1020
1021

®

Summary of Contents for TSG-10

Page 1: ...ment near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam line and safety valve reach a temperatu...

Page 2: ...f the escutcheon onto the steam pipe and screw the steamhead into place Care must be taken not to scratch the steamhead or escutcheon with wrench After the plumbing connections are complete the electrician may finish wiring the unit Figure 2 Plumbing Diagram Installation Instructions Models TSG 7 and TSG 10 02 09 Pub No 203 A 2 Apply a small amount of silicone to prevent movement Apply a small amo...

Page 3: ...f installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The steam outlet pipe should be pi...

Page 4: ...eam Generator CAUTION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actual Cu Ft capaci...

Page 5: ...se circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Generator ...

Page 6: ...Before starting insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the...

Page 7: ...nstallation Models TSG 7 and TSG 10 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Page 8: ...MP Wiring Diagram Models TSG 7 and TSG 10 L1 L2 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse TSG 7 220 7 5 240 208 1 1 31 36 8 8 40 50 Specification Chart TSG 10 375 10 240 208 1 1 42 48 6 6 60 60 1 2 3 4 5 6 7 8 Dip Switch Settings for Multiple Steam Generators on Processor Board Generator 1 1 and 2 up Generator 2 1 down and 2 up Generator 3 1 up and 2 ...

Page 9: ...Steam Generators can be typically mounted within 25 ft of the bathing area Steam Generators should be accessible for service Do not install in attic Do not install generators outside in a moist humid area or in an area where parts may freeze or corrode Steamhead to be mounted 18 above floor or 6 above rim of tub and as far from the seating area as possible Rough in Notes Access 28 L x 18 W x 20 H ...

Page 10: ...OINTING UP WARNING Unit must be installed INDOORS in a DRY NON FREEZING location and with arrows pointing up Service by authrorized personnel only NOTE Read all instructions before installation CAUTION To prevent internal damage hold all fittings securely while making plumbing connections NOTE See Wiring Diagram on reverse side of cover CAUTION Turn off electric before removing cover NOTE This is ...

Reviews: