background image

Optional Auto

Drain Valve

Model TSG-AD

Water Inlet 

" Compression 

Fitting 

¾" Safety  

Relief Valve 

¾" Steam 

Outlet 

Knockouts for 

Electrical Supply Line 

Knockout for 
Control Cable 

Install Upright 

and Level 

®

®

WARNING:

 

Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or 

who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use 
steambath while under the influence of alcohol. 

IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential 
steambath installation. 

Plumbing Installation Instructions

Steambath Generator

Models: TSG-7 and TSG-10

The Steamist “TSG” Generator comes factory assembled, 
carefully wired and tested.

The Plumbing Installation must conform to local and national 
codes. All electrical power should be turned OFF when working 
with Steam Generator.

1. 

Pre-Installation

a) Be sure that the proper size Steam Generator has been 

selected by using the sizing page in the “Full Line 
Brochure,” “Pricing Guide,” “The Generator Sizing 
Guide,” “Architectural Guidelines,” or in the Residential 
Systems/Steambath Product Information section of the 
Steamist website - www.steamist.com.

    CAUTION: An improperly sized Steam Generator may 

NOT produce the amount of steam necessary to reach 
selected temperature.

    IMPORTANT: Refer to page 4 for model required for 

cubic foot rating.

b) The Steam Generator should be located as close as 

possible to the Steamroom/Shower or tub enclosure. 
Steam pipe should NOT exceed twenty-five feet in length. 
If the steam pipe exceeds ten feet, use an appropriate 
pipe insulation rated for a minimum of 212°F. Possible 
locations include Vanity, Closets, or Basement near bath 
area. The serial number plate should be visible and the 
Steam Generator should be accessible for service. Refer 
to Installation Suggestions on page 4. Do NOT install 
Generator outdoors, in a moist, humid area, or in an area 
where parts may freeze or corrode. Also, do NOT install 
near flammable materials such as paints, thinners, 
gasoline, etc.

c) The steam line and safety valve reach a temperature of 

212°F during operation and should be appropriately 
protected to prevent personal injury by accidental 
contact.

2. 

Plumbing Rough-in

 

Plumbing rough-in is required for the water supply and 

steam line; this should be completed before the walls 
are closed. For operation, the “TSG” Steam Generator 
requires a 

" O.D. copper tubing to the fitting on the 

generator for water inlet and a ¾" copper or brass pipe
 for steam outlet.

NOTE: Safety Valve should be connected to a minimum ¾" 
indirect waste or as required by local plumbing codes. In 
the unlikely event this valve should open, the discharge 
must be directed to prevent damage to the home.

a) Water Inlet - A water line should be roughed in 

from existing ½” hot or cold water pipe. Using a ½" 

" tee, cut and solder tee into the existing water 

line (see Figure 4 on page 3). Solder a piece of 
 

" copper tubing into tee. Rough-in for water 

supply is now complete.

b) Steam Outlet - Rough in the steam line using a 

minimum of a ¾" copper or brass pipe; do NOT 
use black iron or galvanized pipe; it will rust and 
discolor the wall of the steambath. The steamhead 
location should be 18" above the shower floor or 6" 
above the rim of the bathtub, as far from the  
seating area as possible.

CAUTION: No shutoff valve can be installed in the steam 
line. Do NOT create traps or valleys in this line which would 
trap condensation and block the flow of steam. The steam 
pipe should be pitched allowing condensation to run back 
toward the Steam Generator (preferred), or toward the 
steamhead.

Figure 1 - Steam Generator

US 

® 

02/09

Pub. No. 203-A

- 1 - 

®

®

®

Summary of Contents for TSG-10

Page 1: ...ment near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam line and safety valve reach a temperatu...

Page 2: ...f the escutcheon onto the steam pipe and screw the steamhead into place Care must be taken not to scratch the steamhead or escutcheon with wrench After the plumbing connections are complete the electrician may finish wiring the unit Figure 2 Plumbing Diagram Installation Instructions Models TSG 7 and TSG 10 02 09 Pub No 203 A 2 Apply a small amount of silicone to prevent movement Apply a small amo...

Page 3: ...f installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The steam outlet pipe should be pi...

Page 4: ...eam Generator CAUTION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actual Cu Ft capaci...

Page 5: ...se circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Generator ...

Page 6: ...Before starting insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the...

Page 7: ...nstallation Models TSG 7 and TSG 10 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Page 8: ...MP Wiring Diagram Models TSG 7 and TSG 10 L1 L2 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse TSG 7 220 7 5 240 208 1 1 31 36 8 8 40 50 Specification Chart TSG 10 375 10 240 208 1 1 42 48 6 6 60 60 1 2 3 4 5 6 7 8 Dip Switch Settings for Multiple Steam Generators on Processor Board Generator 1 1 and 2 up Generator 2 1 down and 2 up Generator 3 1 up and 2 ...

Page 9: ...Steam Generators can be typically mounted within 25 ft of the bathing area Steam Generators should be accessible for service Do not install in attic Do not install generators outside in a moist humid area or in an area where parts may freeze or corrode Steamhead to be mounted 18 above floor or 6 above rim of tub and as far from the seating area as possible Rough in Notes Access 28 L x 18 W x 20 H ...

Page 10: ...OINTING UP WARNING Unit must be installed INDOORS in a DRY NON FREEZING location and with arrows pointing up Service by authrorized personnel only NOTE Read all instructions before installation CAUTION To prevent internal damage hold all fittings securely while making plumbing connections NOTE See Wiring Diagram on reverse side of cover CAUTION Turn off electric before removing cover NOTE This is ...

Reviews: