Protective Covering 

“Remove Before  

Installation”  

Modular Jack 

Knock-outs for 

Strain Relief 

Clamps 

Cable Installation 

on Steam Generator 

Figure 2 

06/07

Pub. No. 554-E

- 2 - 

Printed 

Circuit Board 

Multi-conductor 

Control Cable 

(25 feet) 

¾“ Conduit 

To Control 

 

Locate the previously installed cable and black plastic 

strain relief clamp which is in the control packing box.  

Locate the knock-out on the steam generator for the 

control cable (see Figure 2).

Place strain relief around cable about seven inches 

from the end and insert into the hole.  Remove the 

protective  covering  labeled,  “Remove  before 

installation,” from the modular jack found on the PC 

board.

If  TC-135  is  used  in  conjunction  with  the  optional 

TC-110 control or Dual System, plug the splitter into 

the  modular  jack,  this  will  allow  two  cables  to  be 

plugged into the PC board (see Figure 2).

IMPORTANT:

 When used with the Optional TC-110 

control or Dual System, the Steamist supplied splitter 

must be used. Locally purchased telephone splitters 

will 

NOT 

work and void the warranty.

Remove the protective cap from the multi-conductor 

cable plug. Connect the cable to the modular jack.

Close and secure generator cover.

Locate Telco Jack at female coupler, on back of the 

TC-135  control.    Remove  the  protective  covering 

labeled  “Remove  before  Installation”.    Remove 

protective cap from cable and plug into jack.  Check 

that the orientation of the plug properly aligns with the 

jack.    A  snap  will  indicate  the  plug  is  installed 

correctly (see Figure 2).

WARNING: 

Test  the  control  for  operation  before 

continuing on to the next step.

3. Control and Cable Installation

a)

b)

c)

d)

e)

f)

Peel  adhesive  liner  from  back  of  the  control.  Apply 

the control to the wall. Press firmly and hold for a few 

seconds. 

After the control is in place, apply silicone (supplied) 

around the control to form a water tight seal.

IMPORTANT:

  The  adhesive  on  the  back  of  the 

TC-135  control  will  NOT  seal  this  control.  It  is  the 

responsibility of the installer to seal this control to the 

wall with the supplied silicone. Water damage to the 

control is not covered by the warranty.

g)

h)

Figure 3

Coupler

Control Cable

to Generator

Adhesive Liner

 

E

N

O

CI

LI

S

R A

E L

C

. Z

O   .

L F

  2

/ 1

  t

e N

0 2

5 1

3   .

o N

 

m e

t I

. A

. S

. U

  N

I  

E D

A

M

Figure 4

Steamist splitter  

supplied with Optional 

TC-110 control or Dual 

System. 

 

Reviews: