Protective Covering
“Remove Before
Installation”
Modular Jack
Knock-outs for
Strain Relief
Clamps
Cable Installation
on Steam Generator
Figure 2
06/07
Pub. No. 554-E
- 2 -
Printed
Circuit Board
Multi-conductor
Control Cable
(25 feet)
¾“ Conduit
To Control
Locate the previously installed cable and black plastic
strain relief clamp which is in the control packing box.
Locate the knock-out on the steam generator for the
control cable (see Figure 2).
Place strain relief around cable about seven inches
from the end and insert into the hole. Remove the
protective covering labeled, “Remove before
installation,” from the modular jack found on the PC
board.
If TC-135 is used in conjunction with the optional
TC-110 control or Dual System, plug the splitter into
the modular jack, this will allow two cables to be
plugged into the PC board (see Figure 2).
IMPORTANT:
When used with the Optional TC-110
control or Dual System, the Steamist supplied splitter
must be used. Locally purchased telephone splitters
will
NOT
work and void the warranty.
Remove the protective cap from the multi-conductor
cable plug. Connect the cable to the modular jack.
Close and secure generator cover.
Locate Telco Jack at female coupler, on back of the
TC-135 control. Remove the protective covering
labeled “Remove before Installation”. Remove
protective cap from cable and plug into jack. Check
that the orientation of the plug properly aligns with the
jack. A snap will indicate the plug is installed
correctly (see Figure 2).
WARNING:
Test the control for operation before
continuing on to the next step.
3. Control and Cable Installation
a)
b)
c)
d)
e)
f)
Peel adhesive liner from back of the control. Apply
the control to the wall. Press firmly and hold for a few
seconds.
After the control is in place, apply silicone (supplied)
around the control to form a water tight seal.
IMPORTANT:
The adhesive on the back of the
TC-135 control will NOT seal this control. It is the
responsibility of the installer to seal this control to the
wall with the supplied silicone. Water damage to the
control is not covered by the warranty.
g)
h)
Figure 3
Coupler
Control Cable
to Generator
Adhesive Liner
E
N
O
CI
LI
S
R A
E L
C
. Z
O .
L F
2
/ 1
t
e N
0 2
5 1
3 .
o N
m e
t I
. A
. S
. U
N
I
E D
A
M
Figure 4
Steamist splitter
supplied with Optional
TC-110 control or Dual
System.