06/07
Pub. No. 554-E
- 4 -
Installation Suggestions
START
STOP
�
�
Figure 6
Installation Suggestions
Optional Outside
Installation
TC-110
Control
Steamhead Installation
Steamhead should be mounted
18” above the finished floor or 6”
above the rim of the tub as far
from the bather as possible
All Instructions must be given to the homeowner for future use.
TEMP CONTROL
SET
TEMP
START
STOP
Operating Instructions
Additional Features
Inside Installation
TC-135
Control
. Locate away
from the direct line of shower
spray and do NOT locate
above steamhead.
Operation
Make sure the water and power are turned on. Simply
press the Start/Stop keypad to begin the previously
programmed cycle. Pressing the Start/Stop a second time
will cancel the cycle. After a cycle is started it will take a few
minutes for the Steam Generator to heat-up and begin
producing steam. During operation the display will show
the ambient temperature. The heat light will cycle on and
off as the temperature is maintained.
Programming
Adjustments can be made to the temperature control while
the system is on or off. Any time the temperature is
displayed, it can be adjusted by simply pressing the up or
down keypad. The set temperature can be displayed at any
time by pressing the Set Temp button. All changes made to
the temperature control are stored in memory until changed
again. The temperature range is 50° to 130°F (10°C to
55°C).
Memory
The temperature set point is retained even if there is a
power failure.
Fahrenheit/Celsius
The temperature display may be changed to Fahrenheit or
Celsius by simultaneously pressing and holding the up and
down keypad for 5 seconds while the system is off. The
display will show the current setting “F” or “C” and then
alternate when the change is complete.
Error Message
This control is programmed with a diagnostic feature to help
isolate any potential problems. Error messages E0, E1, E2
and E3, indicate a problem internal to the control. If this
occurs the control should be repaired or replaced. Error
messages E4, E5 and E6 indicated a communication prob-
lem with the steam generator. If this error occurs, check
both ends of the control cable for clean, dry and secure
connections. Dirty contacts can be cleaned with alcohol
and a cotton swab or a toothbrush. This can also happen if
the control is not sealed and the cable connections get wet.