MAX. SAUNA
HEIGHT 8'-0"
NORMAL
SAUNA
HEIGHT 7'-0"
MIN. SAUNA
HEIGHT 6'-2"
5'-0"
AIR
IN
4"
CONCRETE
TILE
36"
18"
6"
AIR
OUT
20"
20"
FENCE
HEATER MIN. CLEARANCE
FROM BENCHES
BENCHES
min. 1"
min. 2"
min. 2"
7
"
Figure 4a
CENTER WALL FENCE INSTALL
Table 1
Model
Heater kW
Minimum
Ceiling
Height
Minimum
Floor Area
in Square
Feet
Maximum
Floor Area
in Square
Feet
Sauna Room
Minimum
Cubic Feet
Sauna Room
Maximum
Cubic Feet
Minimum
Spacing From
Adjacent
Surfaces
SMS-45
SMS-60
SMS-80
4.5 kW
6 kW
8 kW
74 inches
74 inches
74 inches
16
28
40
30
40
65
100
170
250
210
300
425
3 inches
4 inches
5 inches
Wall Mount Heater Installation
11/10
Pub. No. 570-C
Owners Manual
Figure 2
- 3 -
VENTILATION, MIN SQ.IN. INLET AND OUTLET
4.5 Kw 10 SQ.IN.
6 Kw AND 8Kw 20 SQ.IN.
Figure 3
HEATER MIN. CLEARANCE
FROM WALL TO FENCE
3" min.(4.5kW)
4" min.(6 kW)
5" min.(8 kW)
2" min.
FENCE
2" min.
Figure 4
3" min.(4.5kW)
4" min.(6 kW)
5" min.(8 kW)
2" min.
2" min.
2" min.
FENCE
The Sauna Room shall be provided with proper ventilation wall-mounted heaters-minimum clearances, min-max space, and
adequate ventilation.
NOTE: The Sauna Room shall be provided with ventilation according to the diagrams listed above. Installation of all heaters must
adhere to the minimum clearance requirements as listed in this manual.