MAX. SAUNA

 HEIGHT 8'-0"

NORMAL

 SAUNA

 HEIGHT 7'-0"

MIN. SAUNA

 HEIGHT 6'-2"

5'-0"

AIR

IN

4"

CONCRETE

TILE

36"

18"

6"

AIR
OUT

20"

20"

FENCE

HEATER MIN. CLEARANCE
FROM BENCHES

BENCHES

min. 1"

min. 2"

min. 2"

7

"

Figure 4a

CENTER WALL FENCE INSTALL

Table 1

Model

Heater kW

Minimum

Ceiling 

Height

Minimum

Floor Area

in Square

Feet

Maximum

Floor Area

in Square

Feet

Sauna Room

Minimum

Cubic Feet

Sauna Room

Maximum

Cubic Feet

Minimum

Spacing From

Adjacent 

Surfaces

SMS-45

SMS-60

SMS-80

4.5 kW

6 kW

8 kW

74 inches

74 inches

74 inches

16

28

40

30

40

65

100

170

250

210

300

425

3 inches

4 inches

5 inches

Wall Mount Heater Installation 

11/10

Pub. No. 570-C

Owners Manual

Figure 2

- 3 -

VENTILATION, MIN SQ.IN. INLET AND OUTLET
4.5 Kw 10 SQ.IN.
6 Kw AND 8Kw 20 SQ.IN.

Figure 3

HEATER MIN. CLEARANCE
FROM WALL TO FENCE

3" min.(4.5kW)
4" min.(6 kW)
5" min.(8 kW)

2" min.

FENCE

2" min.

Figure 4

3" min.(4.5kW)
4" min.(6 kW)
5" min.(8 kW)

2" min.

2" min.

2" min.

FENCE

The Sauna Room shall be provided with proper ventilation wall-mounted heaters-minimum clearances, min-max space, and 
adequate ventilation.

NOTE: The Sauna Room shall be provided with ventilation according to the diagrams listed above. Installation of all heaters must 
adhere to the minimum clearance requirements as listed in this manual.

Summary of Contents for SMS-45

Page 1: ...SMS 80R 3 11 10 Pub No 570 C 1 Attention Electrician This manual must be left with the owner or operator of the sauna after installation This manual contains installation and operating instructions w...

Page 2: ...cing in the wall cavity behind the heater Observe proper clearances as per Figures 1 5 2 See applicable wiring diagram figures 6 for heater model Heater must be hard wired directly with no pigtails or...

Page 3: ...0 40 65 100 170 250 210 300 425 3 inches 4 inches 5 inches Wall Mount Heater Installation 11 10 Pub No 570 C Owners Manual Figure 2 3 VENTILATION MIN SQ IN INLET AND OUTLET 4 5 Kw 10 SQ IN 6 Kw AND 8K...

Page 4: ...4 500 6 000 8 000 6 000 8 000 8 000 18 8 25 33 3 25 33 3 22 2 240 240 240 240 240 208 1 1 1 1 1 3 10 2 8 2 6 2 8 3 6 3 10 4 SMS 45 SMS 60 SMS 80 240V 1PHASE HEATER SMS 60R 240V 1PHASE HEATER SMS 80R...

Page 5: ...the timer up to 8 hours in advance The timer has a 60 minute time cycle the large print 0 and 1 on the dial If you wish to use the full 60 minute time cycle turn the timer knob clockwise past the 1 s...

Page 6: ...been shorted out the heater will not operate B If the heater has been in operation but ceases to operate 1 Check the circuit breaker to make sure it is on 2 Check the timer to see if it winds down 3...

Page 7: ...me should towels bathing suits buckets or ladles or any other flammable material be placed on or over the heater Use only clean tap water on the sauna stones Do not use any chemically treated water su...

Page 8: ...the original purchase date All costs for removal and reinstallation of the component s on the job site shipment to the factory and shipping back to the job site will be the responsibility of the owner...

Reviews: