background image

Optional Steamist Splitter

for Two Controls

Modular Jack

Protective Covering

“Remove Before

Installation” 

Plug

Optional Auto

Drain Connection

Knockout 

for Auto Drain

¾" Steam

Outlet

Safety

Relief

Valve

Water Inlet

" Compression

Fitting

½" Outlet

When not equipped

with Auto Drain leave

drain line capped 

and closed

Printed

Circuit

Board

Water

Level

Probe

Terminal Strip

for Auto Drain 

Connection

®

®

®

Test Switch

Before starting, insure that the conditions of the following checklist have been met:

The proper size Steam Generator has been selected by 
using the sizing page in the “Full Line Brochure,” “Pricing 
Guide,” or “The Generator Sizing Guide” in the Residen-
tial Systems/Steambath Product Information section of 
the Steamist website - www.steamist.com.

CAUTION: An improperly sized Steam Generator will 
NOT produce the amount of steam necessary to reach 
selected temperature.

The proper voltage Steam Generator has been selected 
(i.e., 208V or 240V). A 208V Generator operating on 
240V will damage the heating element, and a 240V 
Generator operating on 208V will result in a 25% loss
of power.

The Steam Generator is installed in an upright position.

The proper sized 90°C copper wire and circuit breaker 
have been used.

The circuit breaker is NOT a GFI (Ground Fault 
Interrupter) type.

The Steam Generator is properly grounded.

The circuit breaker or disconnect switch is on.

Water supply is open to the Steam Generator.

Electrical Installation Instructions

Checklist

Model: SM-11

Figure 2 - Major Electrical Components

05/11

Pub. No. 327-M

- 2 -

Summary of Contents for SM-11

Page 1: ... proper amperage Refer to chart on page 4 for amperage rating After the walls are complete the Steam Generator and Control can be wired 3 Steam Generator Electrical Installation WARNING All power to the Steam Generator must be turned off a Remove the four screws holding the electrical access cover and remove cover b Locate the supply line knockout Mount proper strain relief into knockout hole see ...

Page 2: ...tems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature The proper voltage Steam Generator has been selected i e 208V or 240V A 208V Generator operating on 240V will damage the heating element and a 240V Generator operating on 208V will result in a 25...

Page 3: ... for future use SMC 150 or TC 150 Control MUST be installed inside the steam room NOTE Unit must be wired with 90 C copper wire in a suitable raceway or if local codes allow provide twist lock plug on a 90 C copper wire cord from genera tor to a 250V 2 pole 3 wire grounding receptacle amperage rating as required Control Cable Route from Control to Steam Generator in a conduit Appropriately fuse pr...

Page 4: ...1 L3 L2 T1 T3 T2 Noise Filter BLK BLK BRN YEL TANK Contactor Relay L1 L2 L3 GND GRN Field Connections NOTES Supplied with Controller Field connections use 90ºC copper wire TEMPERATURE START STOP TEMPERATURE START STOP Supplied with Controller Field connections use 90ºC copper wire Fuses only supplied with 208 Volt Single Phase Generators DS1 DS2 DS3 DS4 GRN YEL AMB RED TIMER ON HEAT ON WATER FILL ...

Reviews: