START
STOP
®
TEMPERATURE
START
STOP
WARNING
HOLD THIS FITTING SECURELY WITH A PIPE
WRENCH WHILE MAKING A PLUMBING
CONNECTION TO THE WATER INLET IN ORDER
TO PREVENT INTERNAL DAMAGE TO THE WATER
SOLENOID VALVE.
009-1054
C
US
®
LISTED 995C
STEAMBATH GENERATOR
MODEL NO.
SERIAL NO.
HEATER LOAD
VOLTS
PH
MAX AMPS
kW
CONTROL CIRCUIT
VOLTS
AMPS
50/60 HZ
SERVICE BY AUTHORIZED PERSONNEL ONLY
A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ
IMPORTANT:
Run the Control Cable through a ¾" conduit. Remove protective cap when making the
final connection to Control.
The Electrical Instructions must be given to the homeowner for future use.
SMC-150 or TC-150
Control
MUST
be
installed inside the
steam room.
NOTE: Unit must be wired with 90°C
copper wire in a suitable raceway, or, if
local codes allow, provide twist lock plug
on a 90°C copper wire cord from genera-
tor to a 250V 2-pole, 3-wire grounding
receptacle (amperage rating as required).
Control Cable
Route from
Control to Steam
Generator in a
¾" conduit.
Appropriately
fuse protected
208/240V field
wiring to Steam
Generator.
Inside Installation
Control should be mounted four
feet from the floor. Select a
location convenient to the
bather but not in a direct line of
Shower or Body Sprays and not
directly above the Steamhead.
SMC-120 or TC-125
Auxilary Outside
Control
®
®
Electrical Installation Instructions
Figure 3 - Typical Installation
Model: SM-11
05/11
Pub. No. 327-M
- 3 -