3
START
STOP
TIME
TEMP
SENSOR
HEAT
2
1
6
TIME / TEMP
4
5
Installation and Operating Instructions
C
US
®
02/09
Pub. No. 120-F
- 1 -
Control Features
1.
Temperature Sensor: Measures temperature inside
steamroom.
2.
Temperature/Timer Display: Counts down remaining
minutes and shows programmed minutes, set temperature,
and
room
temperature.
3.
Heat Light: Indicates the generator is producing steam when
illuminated. The heater in the generator and the heat light
will cycle ON/OFF as the temperature is maintained
automatically in the steamroom.
4.
Increase/Decrease, Temperature and Timer Set Keypads:
Press for a second to view the previously selected time/temp.
Press and hold to program the desired minutes or setpoint
temp.
5.
Start/Stop Keypad: Press to start programmed cycle, press
again to cancel cycle.
6.
Time/Temp Keypad: Press to select between time and
temperature.
Steambath Control
Installation Instructions
Model: DSC-425
DSC-425 Digital Timer and Digital Temperature Control
IMPORTANT: This control MUST be installed inside the steam-
room for proper operation of the system.
The Digital ON/OFF Elapsed Timer/Temp Control is designed
to be connected and operated only with the Steamist SM
Steambath Generator and cannot be used with any other
equipment.
CAUTION: All electrical connections must be performed by a
licensed electrician in accordance with Local and National
Electrical Codes. Power must be OFF until all wiring is complete.
1. Remove the cover from the Steambath Generator. Insert
multi-conductor cable with strain relief (provided) through
cabinet knockout and secure the cable to the top of the
steambath generator leaving 8" of cable inside the generator.
Remove the protective covering labeled “Remove Before
Installation” from the Telco Jack found on the Circuit Board.
Remove protective cap from plug and insert Steamist cable
into Telco Jack; check that the orientation of the plug properly
aligns with the jack. A snap will indicate the plug is installed
correctly (see Figure 1). Close and secure Generator cover.
NOTE: The DSC-425 Control should be stored in the
protective box until the wall is completed and is ready
to be installed.
2. Select a mounting location inside the steamroom for the
DSC-425 Control, 4 feet above the floor, convenient to
the bather. Do NOT locate in direct line of shower head
spray or above steamhead (see Figure 6). Mount 2
metal, gangable switch boxes, twinned together (not
provided) in this location. Do NOT use a 4x4 electrical
box.
WARNING:
Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or
who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use
steambath while under the influence of alcohol. For additional Important Safety Information, please see a separate
instruction sheet Pub. No. 199.
!
IMPORTANT: The DSC-425 Controls will only function with one of the following Steamist Generator models: SM-46, SM-79, SM-4,
SM-5, SM-7, SM-8, SM-11, SM-12, SM-15, System-18, System-24, System-30, with or without the InstaMist feature.
®