background image

STEALTH DIGI-CUT45PFC

4  PRODUCT DESCRIPTION

4.1  The voltage of the output ends is very high. Don’t touch with the output ends, cutting 

 

torch and other conductive parts while setting up an electric circuit.

4.2  For the safety of the equipment and the persons, the customer must correctly make 

 

grounding or protection according to the power supply system:using 4 mm2 lead to 

 

connect the protection grounding of the cutting machine.

4.3  Cutting operating should be carried out in dry and good ventilating area. The 

 

surrounding objects should be not less than 0.5m away from the cutting machine.

4.4  Before cutting , the operator should read the operation instructions carefully and use 

 

the machine correctly.

5  PANEL FUNCTION DIAGRAMS

FRONT PANEL

BACK PANEL

  2. For the safety of the equipment and the persons, the customer must correctly make grounding        
or protection according to the power supply system:using 4 mm

2

  lead  to  connect  the  protection          

grounding of the cutting machine.
   3. Cutting operating should be carried out in dry and good ventilating area. The surrounding               
objects should be not less than 0.5m away from the cutting machine.
   4 . Before cutting , the operator should read the operation instructions carefully and use the                 
machine correctly.

5. THE SKETCH OF FUNCTION AND CONNECT ING

1. 

indication of cutting current  2.power indication 3. warning indication 4. cutting/testing gas switch  

5. cutting current regulator      6. cutting torch cable  8. workpiece cable 
9. nameplate  10. air pressure-reduced valve 11. pressure air entrance 12. fan                                 
 13. indication of air pressure-reduced valve 14. grounding column 15.  input cable  16,power switch  

 17.low air pressure indication   18. indication of PSI OK TO CUT minimum 19.FUSE 

BACK PANEL

FRONT PANEL

11

12

14

15

10

16

13

2

7

3

4

5

1

6

8

air compressor

torch

workpiece

oo

6

8

19

19

17

13

2

3

4

5

1

17

18

10

10

13

2

7

3

4

5

1

19

19

17

13

2

3

4

5

1

17

18

  2. For the safety of the equipment and the persons, the customer must correctly make grounding        
or protection according to the power supply system:using 4 mm

2

  lead  to  connect  the  protection          

grounding of the cutting machine.
   3. Cutting operating should be carried out in dry and good ventilating area. The surrounding               
objects should be not less than 0.5m away from the cutting machine.
   4 . Before cutting , the operator should read the operation instructions carefully and use the                 
machine correctly.

5. THE SKETCH OF FUNCTION AND CONNECT ING

1. 

indication of cutting current  2.power indication 3. warning indication 4. cutting/testing gas switch  

5. cutting current regulator      6. cutting torch cable  8. workpiece cable 
9. nameplate  10. air pressure-reduced valve 11. pressure air entrance 12. fan                                 
 13. indication of air pressure-reduced valve 14. grounding column 15.  input cable  16,power switch  

 17.low air pressure indication   18. indication of PSI OK TO CUT minimum 19.FUSE 

BACK PANEL

FRONT PANEL

11

12

14

15

10

16

13

2

7

3

4

5

1

6

8

air compressor

torch

workpiece

oo

6

8

19

19

17

13

2

3

4

5

1

17

18

10

10

13

2

7

3

4

5

1

19

19

17

13

2

3

4

5

1

17

18

1.  Cutting current indicator 

2.  Power ON/OFF 

3.  Warning light

4.  Cutting/testing gas switch 

5.  Cutting current indicator 

6.  Cutting torch cable

8.  Workpiece cable 

9. Nameplate 

10. Air pressure-reducing valve

11. Air IN pressure

12. Fan

13. Air pressure-reducing valve

 indicator

14. Grounding column

15. Input cable

16. Power switch

17. Low air pressure indicator

18. PSI OK TO CUT (minimum)

 indicator

19. Fuse

Summary of Contents for digi-cut45pfc

Page 1: ...DC INVERTER AIR PLASMA CUTTING MACHINE Part No 9031 DIGI CUT45PFC OPERATING INSTRUCTIONS Suitable for 220 240V...

Page 2: ...ACHINE WHEN REPAIRING OR ADJUSTING INSPECT BEFORE EVERY USE ONLY USE IDENTICAL REPLACEMENT PARTS 10 FOLLOW ALL MANUFACTURER S RULES ON OPERATING SWITCHES AND MAKING ADJUSTMENTS 11 ALWAYS WEAR PROTECTI...

Page 3: ...nthly temperature 20 C 2 2 2 Ambient temperature 10 C 40 C 2 2 3 The cutting site should have no harmful gas chemicals moulds and inflammable matter explosive and corrosive medium 2 2 4 Operating in r...

Page 4: ...ut cable 16 power switch 17 low air pressure indication 18 indication of PSI OK TO CUT minimum 19 FUSE BACK PANEL FRONT PANEL 11 12 14 15 10 16 13 2 7 3 4 5 1 6 8 air compressor torch workpiece oo 6 8...

Page 5: ...gain 6 3 Select a suitable current with the current control knob for the thickness of the material and one that is suitable for the consumables fitted to the torch 6 4 CUTTING Hold the cutting torch o...

Page 6: ...o low or the machine fails No output of welder 1 Over current protection 1 Over load using 2 Welder fails 2 Maintenance in manufacturer or service centre Output current 1 Input voltage is low 1 Stabil...

Page 7: ...o not touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del...

Page 8: ...la o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci n de poder de la m quina antes de iniciar cualquier servicio D branchez le c...