ASSEMBLY INSTRUCTIONS

1

Fig A

12  / 31 cm

2

3

Unpack the air compressor unit. Inspect the unit for damaged. If the unit has been damaged, contact the 

retailer immediately.
Check the air compressor’s identification label to ensure that you have purchased the intended model and 

that it has the required pressure rating for its intended use.

Air compressor
Owner's manual

The carton should contain:

Positioning of the air compressor

Connect air hose to compressor

Note:

Position the air compressor (1) near an electrical outlet (2) (Fig A).
The compressor must be at least 12”(31cm) from any wall (3) or 

obstruction, in a clean, well-ventilated area to ensure sufficient air flow 

and cooling (Fig A).
Place the air compressor on the floor or a hard,level surface.The air 

compressor must be level to ensure proper drainage of the moisture in the 

tank.

Connect the air hose (1) to the compressor’s quick coupler (2) with the 

quick conncetor (3) (Fig B).

Air hose and quick connector are not provided, need to be purchased 

sepa rately. Apply plumber's tape on all the threads to prevent air 

leakage.

1.
2.

3.

1.

High pressure air could result in death or serious injury. Never operate above maximum 

operating pressure of the spray gun or tool.

Hot compressor surfaces could result in serious injury. Allow compressor to cool before 

touching.

WARNING

WARNING

Notice
If the pump has been transported or turned upside down (even partially), allow the pump to sit 

in a normal, upright position for approximately 10 minutes before starting.

Risk of serious eye injury from moisture and debris. Always wear ANSI Z87.1 safety 

goggles when opening drain valve.

High pressure air could result in death or serious injury. Shut off unit, unplug and 

release air pressure prior to servicing.

High pressure air containing water condensation could result in minor or moderate 

injury. Do not spray at any person.

WARNING

WARNING

CAUTION

• 

• 

• 
• 

Summary of Contents for 3300381

Page 1: ...essor To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference Toll Free Helpline OPERATOR S MANUAL CAUTION 1 888 899 0146 Product Mode...

Page 2: ...ns Read all instructions and follow them with use of this product CFM Cubic Feet per Minute This compressor is rated in accordance with ISO 1217 displacement compressors acceptance tests TECHNICAL SPE...

Page 3: ...sure that the procedure work method or operating technique that you choose does not render the compressor unsafe The safety alert symbol indicates a potential hazard to personal injury A signal word D...

Page 4: ...erious injury Risk of serious eye injury Always wear ANSI Z87 1 approved safety goggles when using air compressor Do not spray any part of the body Shock risk could result in death or serious injury O...

Page 5: ...r Pressure Regulator G Outlet Pressure Gauge F Tank Pressure Gauge D ON OFF Switch H Quick Coupler B Air Compressor Pump A Electrical Motor J Air Tank I Drain Valve C Safety Valve C B I G K H E A F J...

Page 6: ...wise to decrease the pressure Tank Pressure Gauge The gauge measures the pressure level of the air that is stored in the tank It cannot be adjusted by the operator and it does not indicate the pressur...

Page 7: ...Connect the air hose 1 to the compressor s quick coupler 2 with the quick conncetor 3 Fig B Air hose and quick connector are not provided need to be purchased sepa rately Apply plumber s tape on all...

Page 8: ...unit is noly requiresd prior to first use Fig F After 30 minutes turn off the ON OFF switch Close the tank drain valve 1 by turning it clockwise Fig G Set the ON OFF switch to the ON position The air...

Page 9: ...Set the ON OFF switch to the ON position and allow the tank pressure to build Motor will stop when tank pressure reaches cut out pressure Turn the air pressure regulator knob clockwise until desired p...

Page 10: ...ect and wind up the power cord Clean the ventilation openings on the motor enclosure with a damp cloth Drain all moisture from the tank Pull the pressure safety valve to release all pressure from the...

Page 11: ...gauge and cord length Turn the air compressor off unplug the power cord and wait until the motor has cooled down Plug in the power cord only after the motor has cooled down and wait at least 5 minutes...

Page 12: ...equate Cooling surfaces are dirty The valve is leaking Check the fittings with soapy water Tighten or reseal leaking fittings apply plumber s tape on threads Do not over tighten Close the drain valve...

Page 13: ...13 EXPLODED VIEW...

Page 14: ...Power Cord Plug Screw M5 12 Quick Coupler Check Valve Pressure Regulator Knob Screw M4 10 1 1 1 2 1 1 1 1 3 1 8 1 2 3 1 Description Qty No 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Pressure Regulat...

Page 15: ...dress below and call 1 888 899 0146 for instructions prior returning this item to the store or sending back to We will inspect the product and contact you within 72 hours to give you the results of ou...

Reviews: