Description of the operating modes

12 V AGM mode

The 12 V AGM mode is suitable for charging rechargeable 12 V AGM batteries from 
30 Ah (please observe the information of the manufacturer of the battery). Continue 
to press the MODE button (8) until LED (6B) flashes. After approx. 2 seconds the LED 
is constantly on and the charging procedure starts. The charging current is 16 A. The 
final charge voltage is 14.7 V. The charging status is indicated by LEDs (1). If all LEDs 
are constantly on, the battery is full.

12 V SLA/Gel mode

The 12 V SLA/Gel mode is suitable for charging rechargeable 12 V lead-acid and lead-
gel batteries from 30 Ah (please observe the information of the manufacturer of 
the battery). After connecting the charger to the power supply, the SLA/Gel mode is 
automatically preset. Otherwise continue to press the MODE button (8) until LED (6A) 

Operation and display elements

The Battery Charger SH-3.160 is equipped with a clear operation and display panel. 
The LEDs inform you about the chosen operating mode, the charging status of the 
rechargeable battery as well as a short-circuited, defective or reverse-poled rechar-
geable battery at any time.

 

 

Status of the charging mode indicators

flashes. After approx. 2 seconds the LED is constantly on and the charging procedure 
starts. The charging current is 16 A. The final charge voltage is 14.4 V. The charging 
status is indicated by LEDs (1). If all LEDs are constantly on, the battery is full.

12 V Lithium mode

The 12 V Lithium mode is suitable for charging rechargeable 12 V LiFePO

4

 batteries 

from 30 Ah with integrated battery management system (please observe the infor-
mation of the manufacturer of the battery). Continue to press the MODE button (8) 
until LEDs (6A) and (6B) flash. After approx. 2 seconds the LEDs are constantly on 
and the charging procedure starts. The maximum charging current is 16 A. The final 
charge voltage is 14.4 V. The charging status is indicated by LEDs (1). If all LEDs are 
constantly on, the battery is full.

12 V Calcium/Boost mode 

The 12 V Calcium/Boost mode is suitable for charging rechargeable 12 V calcium 
batteries from 30 Ah

 

or for regenerating deep discharged/sulphated rechargeable  

12 V lead-acid batteries from 30 Ah (please observe the information of the manu-
facturer of the battery). Continue to press the MODE button (8) until LED (7) flashes. 
After approx. 2 seconds the LED is constantly on and the charging procedure starts. 
The maximum charging current is 16 A. The final charge voltage is 16 V. The char-
ging status is indicated by LEDs (1). If all LEDs are constantly on, the rechargeable  
battery is full. 

Regeneration mode

If a deep discharged rechargeable battery is connected to the charger, the regenera-
tion mode is the first mode to start. Low charging currents are used to try and bring 
the deep discharged rechargeable battery to a normal battery voltage again. When 
the battery reaches a normal voltage, the charger will continue charging using the 
regular process. 

Defective rechargeable batteries

The charger recognises defective rechargeable batteries automatically. In this case 
the selected charging programme will not be started. LED (4) is on.

Protection against short circuits and reverse polarity 

The charger recognises a short circuit or a battery which has been connected with 
wrong polarity automatically. In this case the selected charging programme will not 
be started. LED (2 resp. 3) is on.

 

Charging status indicators

 

Short circuit of connection  

 cable

 

Connection cable with  

 

reverse polarity

 

Battery defective

 

Operating display

 

Charging mode indicators

 

12 V Calcium/Boost mode

 

Mode selection

1
2

3

4
5
6
7
8

 

12 V SLA/Gel mode

 

12 V AGM mode

 

LED 6A and 6B flash:

 

12 V Lithium mode

6A
6B

6C

7

6

8

4

3

2

1

5

i

6B

6A

6C

i

The battery charger has an auto-memory-function. Following a  
supply voltage failure, it ensures that the device will automatically 
return to the previously selected mode after power is restarted.

 

3 years

 

manufacturer’s warranty. Rechargeable batteries and batteries excluded.     More information at

 

www.ivt-hirschau.de

Summary of Contents for SH-3.160

Page 1: ...Bedienungsanleitung Batterie Ladeger t SH 3 160 Instruction Manual Battery Charger SH 3 160 DE GB Article no 331600 3...

Page 2: ...Sie es umweltgerecht Designed in Germany Powered by IVT Betrieb Der Betrieb unter widrigen Umgebungsbedingungen ist unter allen Umst nden zu vermeiden Widrige Umgebungsbedingungen sind Umgebungstempe...

Page 3: ...ale Ladestrom betr gt 16 A Die Ladeschlussspannung betr gt 14 4 V Der Ladestatus wird durch die LEDs 1 angezeigt Wenn alle LEDs konstant leuchten ist der Akku voll 12 V Calcium Boost Modus Der 12 V Ca...

Page 4: ...ein defekter Akku durch die LED 4 Trennen Sie nach dem Ladevorgang das Ladeger t von der Netzspannung Entfernen Sie anschlie end die Klemme vom Minuspol des Akkus und danach vom Pluspol Ladekurven St...

Page 5: ...deren Formen der Verwertung von Altger ten leisten Sie einen wichtigen Beitrag zum Schutze unserer Umwelt Bitte erfragen Sie bei der Gemeindeverwaltung die zust ndige Entsorgungsstelle Hinweis zum Umw...

Page 6: ...environmental conditions must be avoided under all circumstances Unfavourable environmental conditions include ambient temperatures above 40 C flammable gases solvents vapours dust and relative humid...

Page 7: ...harging status is indicated by LEDs 1 If all LEDs are constantly on the battery is full 12 V Calcium Boost mode The 12 V Calcium Boost mode is suitable for charging rechargeable 12 V calcium batteries...

Page 8: ...After charging disconnect the battery charger from the power supply Then remove the terminal from the minus pole of the rechargeable battery and then from the plus pole i Please strictly observe any a...

Page 9: ...aterials or other forms of scrap usage you are making an important contribution to the protection of the environment Please ask your local authorities for the appropriate disposal center Environmental...

Page 10: ...st function for reactivating deep discharged lead batteries Schutz gegen Kurzschluss Verpolung und berladung Protection against short circuit reverse polarity and overcharging Robustes Geh use mit IP...

Page 11: ...taudte Hirsch Designed in Germany Powered by IVT IVT Innovative Versorgungstechnik GmbH Dienhof 14 D 92242 Hirschau fon 49 0 9622 71991 0 fax 49 0 9622 71991 20 info ivt hirschau de www ivt hirschau d...

Reviews: