45
Technical Training Department
©2003
Ashland City, Tennessee
SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
Part Name
Number
Voltage
Amperes
XFMER Secondary 24 V
1.5
Field Output 24 V
11.5
Inducer (Blower)
194408-0
120 VAC
1.7
ECO (Part of Upper
Temperature Sensor)
194396
24 V - Opens at 203° ±
5.4°F Closes ± 193° F
0.3
Main Gas Valve
24 VAC
1.5
2.2 FLA
3.5 LRA
Igniter
194405
120 VAC
2
OPT Power Venter
120 VAC
14.5 FLA
26.0 LRA
120 VAC
Electrical Information
Integrated Water
Heater Control
(Temperature Control
Board)
194393-0
Inducer (Blower)
194408
SBN Models
Part No.
Pressure Setting To
Close Switch (Inches
W.C.)
366
194411-0
(-) 1.60 ± .10"
275
194411-1
(-) 2.00" ± .10"
310
194411-2
(-) 1.75" ± .10"
120, 200, 250, 390
194411-3
(-) 2.40" ± .10"
154, 180, 199
194411-4
(-) 2.60" ± .10"
-
194411-5
(-) 2.50" ± .10"
Draft Proving (Pressure) Switch Table