TEST 4 - UPPER TEMPERATURE PROBE CONTINUITY CHECK
Conditions:
Power On - Water below tempera-
ture set point.
Red, heater control “Reset Status”
LED-OFF
“Call For Heat” LED off.
TEST 4
Upper Temperature probe continuity check
Red wire to red wire - Turn supply power "Off" for this test
If…
...then
test indicates
no continuity
replace probe.
continuity
is indicated
probe should be okay (also verify Ohms
resistance for water temperature). (Reading will
be approximate.)
TEST 3
Continuity check of ECO (energy cut-off, high limit)
Black to Black wires of upper probe. Power is off.
If…
...then
continuity
is indicated
opens at 203° F; closes at 193° F. If water is
below 193° F, continuity is correct.
continuity
is not present
replace ECO sensor, if water temperature is
below 193° F.
water is less than 120° F
•
reset status LED should be on.
•
replace heater control if control will not manually
reset.
TEST 3 - CONTINUITY CHECK OF HIGH LIMIT (ECO)-
CONTINUED
° F
Ohms
70°
11,884
120°
3,759
140°
2,488
180°
1,169
Ohms Resistance Table