background image

4

  CAUTION

This tank, as all tanks, will eventually leak.  Do not install without
adequate drainage provisions where water flow will cause
damage.  Note: normal condensation from a tank may appear
to be a leaking tank.

WATER PIPING

This tank is design certified to be used with a potable water
system.  When connecting water piping with solder joints use
only lead free solder.

  WARNING

HOTTER WATER CAN SCALD: Water heating tanks are intended
to produce hot water.  Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact.
Some people are more likely to be permanently injured by hot
water than others.  These include the elderly, children, the
infirmed, or physically handicapped.  If anyone using hot water
in your home fits into one of these groups or if there is a local
code or state law  requiring a certain temperature water at the
hot water tap, then you must take special precautions.  In
addition to using the lowest possible temperature setting that
satisfies your hot water needs, some type of tempering device,
such as a mixing valve, should be used at the hot water taps
used by these people or at the tank.

  WARNING

This tank shall not be connected to any heating systems or
component(s) previously used with a non-potable water heating
appliance.

If this tank is also used for space heating applications, all piping
and components connected to the tank shall be suitable for
use with potable water.

This appliance has been design certified as a solar booster
tank complying with Standards for Safety - UL174. The particular
application of this appliance described (above paragraph) may
be subject to review and approval by local code officials.

  WARNING

Toxic chemicals such as used for treatment of boilers or non-
potable water heating appliances shall never be introduced
into a potable water space heating system.

  WARNING

When the system requires water at temperatures higher than
required for other uses, a means such as a mixing valve shall
be installed to temper the water for those uses in order to reduce
scald hazard potential.  Mixing valves are available at plumbing
supply or hardware stores. Follow manufacturer’s instructions
for installation of these valves.

FIGURE 3

The tank will work better if you keep the hot water runs short.
You will also get hot water faster and with less heat loss.

The illustration shows the correct valves and fittings that you
will need to install the tank.  Threaded (3/4”) water connections
are supplied through the tank top.

FIGURE 4

1. Buy the fittings that you need to connect the pipes.

Remember that you have to connect both the hot and cold
water pipes.

2. Apply a light covering of pipe joint compound to each outside

thread before making connection.

3. Connect the cold water supply pipe to the cold water inlet of

your tank as follows:

a.

Look at the top cover of the tank. The hot and cold
connections are marked there.

b.

A non-metallic dip tube is supplied to carry cold water
from the tank top to the bottom.  Be sure that it is in the
cold water inlet.

c.

If using copper tubing, solder tubing to an adapter
BEFORE you attach the adapter to the cold water inlet.
DO NOT solder the cold water supply pipe directly to
the cold water inlet connection.  It might harm the dip
tube.

d.

The cold water supply line must have a shut-off valve
and union.

4. Use a union to connect the hot water supply pipe to the

tank’s hot water outlet.

  CAUTION

Operating an empty or partially filled tank will result in damage
to the tank.

If a tank is installed in a closed water system; such as one
having a back flow preventer, check valve or water meter with
check valve in the cold water supply line, means shall be
provided to control thermal expansion.  Contact the water
supplier or local plumbing contractor on how to control this
situation.

  WARNING

INSTALLATION IN RESIDENTIAL GARAGES: The tank must be
located and/or protected so it is not subject to physical damage
by a moving vehicle.

FILLING THE GEOTHERMAL STORAGE

TANK WITH WATER

1. Close the tank drain valve.  The drain valve is on the lower

front of the tank.

2. Open the cold water supply to the tank.  NOTE: THIS VALVE

MUST BE LEFT OPEN WHEN THE TANK IS IN USE.

Summary of Contents for 198067-000

Page 1: ...a qualified installer service agency or the local utility RATING PLATE A rating plate identifying the manufacturer of the tank will be found above the drain valve When referring to the tank always have the information listed on the rating plate readily available Fill in that information here MODEL NO _______________________________________ SERIAL NO _______________________________________ INSTALLA...

Page 2: ...Regulation 7 Temperature Settings 6 Temperature Adjusting 6 Resetting High Limit Temperature Shut Off System 6 7 MAINTENANCE 7 8 Draining 7 Element 7 Element Replacement 7 Anode 7 8 Water Heater Sounds 8 Repair Parts Illustration and Schedule 8 Repair Parts Schedule 8 TYPICAL INSTALLATION Check all connections for leaks Consult the local utility company to examine installation for propriety and sa...

Page 3: ...inate at an adequate drain Must not have any valve between the relief valve and tank When installing the temperature pressure relief valve use two or three turns of teflon tape or other suitable thread sealer around the threaded end of the valve FIGURE2 WARNING The temperature pressure relief valve should be manually opened once a year Caution should be taken to ensure that 1 no one is in front of...

Page 4: ... as a mixing valve shall be installed to temper the water for those uses in order to reduce scald hazard potential Mixing valves are available at plumbing supply or hardware stores Follow manufacturer s instructions for installation of these valves FIGURE3 The tank will work better if you keep the hot water runs short You will also get hot water faster and with less heat loss The illustration show...

Page 5: ...the water comes out You must not turn the electricity on until the tank is full of water IF ANYAIR IS LEFT IN THE TOP OF THE TANK THE TOP HEATING ELEMENT WILL BURN OUT RIGHTAWAY 4 Check all the new water piping for leaks Fix as needed WIRING OF ELEMENT Determine voltage and wattage from the rating plate attached to the tank All external wiring connection and overcurrent protective devices must be ...

Page 6: ...r if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs some type of tempering device such as a mixing valve should be used at the hot water taps used by these people or at the tank Mixing valves are available at plumbing...

Page 7: ...ket when you replace the element 5 Install new element 6 Reconnect the wires as they were 7 Fill the tank following the filling directions on page 7 Fill the tank with water BEFORE you turn on the electric supply ANODE The anode rod is used to protect the tank from corrosion Most hot water tanks are equipped with an anode rod The submerged rod sacrifices itself to protect the tank Instead of corro...

Page 8: ...e 4 Voltage 5 Part number WATER HEATER SOUNDS 1 The tank is equipped with an immersion heating element for fastest recovery If the tank occasionally makes noises this is not a defect or a safety hazard 2 Lime or scale has accumulated on the heating element causing a hissing sound Element scale removal can be accomplished by using vinegar or by scraping ITEM NO PART DESCRIPTION 1 Primary Anode 2 1 ...

Reviews: