TYPICAL INSTALLATION .................................................................................................................................................................. 2
INSTALLATION ............................................................................................................................................................................... 3-5

Local Codes .............................................................................................................................................................................. 3
Temperature-Pressure Relief Valve .......................................................................................................................................... 3
Locating the Storage Tank ...................................................................................................................................................... 3-4
Water Piping ........................................................................................................................................................................... 4-5
Filling the Tank with Water ........................................................................................................................................................ 5
Wiring of Elements .................................................................................................................................................................... 5
Thermostat ................................................................................................................................................................................ 5

OPERATION ................................................................................................................................................................................... 6-7

Temperature Regulation ........................................................................................................................................................... 7
Temperature Settings ............................................................................................................................................................... 6
Temperature Adjusting .............................................................................................................................................................. 6
Resetting High Limit (Temperature) Shut Off System ........................................................................................................... 6-7

MAINTENANCE .............................................................................................................................................................................. 7-8

Draining ..................................................................................................................................................................................... 7
Element ..................................................................................................................................................................................... 7
Element Replacement .............................................................................................................................................................. 7
Anode ..................................................................................................................................................................................... 7-8
Water Heater Sounds ............................................................................................................................................................... 8

Repair Parts Illustration and Schedule ............................................................................................................................................ 8

Repair Parts Schedule .............................................................................................................................................................. 8

TYPICAL INSTALLATION

Check all connections for leaks.  Consult the local utility company to examine installation for propriety and safety.

TABLE OF CONTENTS

FIGURE 1

Summary of Contents for 198067-000

Page 1: ...a qualified installer service agency or the local utility RATING PLATE A rating plate identifying the manufacturer of the tank will be found above the drain valve When referring to the tank always have the information listed on the rating plate readily available Fill in that information here MODEL NO _______________________________________ SERIAL NO _______________________________________ INSTALLA...

Page 2: ...Regulation 7 Temperature Settings 6 Temperature Adjusting 6 Resetting High Limit Temperature Shut Off System 6 7 MAINTENANCE 7 8 Draining 7 Element 7 Element Replacement 7 Anode 7 8 Water Heater Sounds 8 Repair Parts Illustration and Schedule 8 Repair Parts Schedule 8 TYPICAL INSTALLATION Check all connections for leaks Consult the local utility company to examine installation for propriety and sa...

Page 3: ...inate at an adequate drain Must not have any valve between the relief valve and tank When installing the temperature pressure relief valve use two or three turns of teflon tape or other suitable thread sealer around the threaded end of the valve FIGURE2 WARNING The temperature pressure relief valve should be manually opened once a year Caution should be taken to ensure that 1 no one is in front of...

Page 4: ... as a mixing valve shall be installed to temper the water for those uses in order to reduce scald hazard potential Mixing valves are available at plumbing supply or hardware stores Follow manufacturer s instructions for installation of these valves FIGURE3 The tank will work better if you keep the hot water runs short You will also get hot water faster and with less heat loss The illustration show...

Page 5: ...the water comes out You must not turn the electricity on until the tank is full of water IF ANYAIR IS LEFT IN THE TOP OF THE TANK THE TOP HEATING ELEMENT WILL BURN OUT RIGHTAWAY 4 Check all the new water piping for leaks Fix as needed WIRING OF ELEMENT Determine voltage and wattage from the rating plate attached to the tank All external wiring connection and overcurrent protective devices must be ...

Page 6: ...r if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs some type of tempering device such as a mixing valve should be used at the hot water taps used by these people or at the tank Mixing valves are available at plumbing...

Page 7: ...ket when you replace the element 5 Install new element 6 Reconnect the wires as they were 7 Fill the tank following the filling directions on page 7 Fill the tank with water BEFORE you turn on the electric supply ANODE The anode rod is used to protect the tank from corrosion Most hot water tanks are equipped with an anode rod The submerged rod sacrifices itself to protect the tank Instead of corro...

Page 8: ...e 4 Voltage 5 Part number WATER HEATER SOUNDS 1 The tank is equipped with an immersion heating element for fastest recovery If the tank occasionally makes noises this is not a defect or a safety hazard 2 Lime or scale has accumulated on the heating element causing a hissing sound Element scale removal can be accomplished by using vinegar or by scraping ITEM NO PART DESCRIPTION 1 Primary Anode 2 1 ...