![Starwin V9 OTM45 Installation And User Manual Download Page 44](http://html1.mh-extra.com/html/starwin/v9-otm45/v9-otm45_installation-and-user-manual_1366763044.webp)
44
Copyright © 2021 China Starwin
Figure 7-31: Event Log section
8
System Maintenance
Regular periodic maintenance of the system is required to keep it in best working conditions for
a long time. Table 5-1 represents the required periodical maintenance actions.
Table 7-1: Required Periodical Maintenance Actions
Period
System Part
Maintenance Actions
Daily
Antenna Radome
Radome surface damage absence checking
Daily
Antenna Radome
Radome surface cleaning from dust by damp cloth
Daily
Antenna Radome
Wiping rain water, remaining snow and condensed
water from radome surface by dry clean cloth
Weekly
Cables
Available damages and fixation loosening checking
Weekly
Cables
Waterproof condition of outdoor connectors and
cables checking
Monthly
Antenna
Robustness of the fastening between the antenna and
the vehicle body checking
Every 6 months
Components
Damage absence of the equipment parts checking
Every 6 months
Components
Antenna transmission parts lubrication
Every 6 months
Power up
If the equipment is not used for a long time a
periodical system powering is required to ensure all
elements (indicators, display, fan and other
components) are working and provide the proper
system operation.
Every 6 months
Static test
System monitoring information check-up to confirm
the complete working status
Every 6 months
Static test
Satellite link availability test