Instruction Manual
51
Name/Description: An identifier for the R-Port module. Like the number assignment, it
is for ease of administration only.
Baud (bps): This is the communication speed for the device, and the setting here must
match the setting on the module itself. All common baud rates between 300 and
115,200 bps are supported.
Mode: Sets the character framing scheme that the SV1115IPEXT will use with the
R-Port module. You can choose from the following selections:
8N1: Eight bits, no parity, one stop bit (default and most common).
7N1/701/7E1/7M1/7S1: Seven bits, (none/odd/even/mark/space) parity, one stop bit.
8N1/801/8E1/8M1/8S1: Eight bits, (none/odd/even/mark/space) parity, one stop bit.
8N2: Eight bits, no parity, two stop bits.
Force DCD: Forces the Carrier Detect signal to be active at all times. Normally, DCD
becomes active when a new user connects and is dropped when the last user
disconnects (a response that is similar to many modems). When active, the device will
logout and reset itself if the carrier signal is lost, increasing security. Note that this may
not work with all devices and could impair proper operation in some circumstances.
The default setting is off.
Console Log: Clicking this link will open a separate Web page that will display the
last 200 characters committed to that device’s console log. Note that existing data is
overwritten automatically when the 200 character limit is reached.
IPMI: Shows the IPMI command interface for the device, if applicable. You can make
as many changes as needed on this menu at one time, before applying your changes.
Once you are satisfied with the changes you have made, click Commit changes to
apply the new settings. Click Refresh at any time to see an updated list of attached
R-Port modules.